Comfortboard 80
- Why it surfaced
- Noncombustible · ASTM E136 and CAN/ULC S114 · The findings apply to the insulation material. Verify fire requirements of the complete exterior wall.
- Published evidence
Nexus Pavilion · Decision Intelligence
Compare insulation depth, fire evidence and moisture behavior across five exterior wall boards.
Qualifying board 5 in · R-21 calculated
Documented sizes 1, 1.25, 1.5, 2, 2.5, 3, 4, 5 in
U.S. and Canada · North American sheet. R-4.2/in at 75°F · ASTM C518 (C177), as reported
Apparent conductivity 0.034 W/(m·K) · calculated from the reported nominal inch or per-inch rate under its original test conditions.
Comfortboard 80 technical data sheet · p. 2, Thermal Resistance and Dimensions
Qualifying board 4 in · R-20 published
Documented sizes 0.75, 1, 1.5, 2, 2.5, 3, 4 in
U.S. grade · Canadian C-series is separate. U.S. thickness table · 180-day C518 basis at 75°F
Apparent conductivity 0.029 W/(m·K) · calculated from the reported nominal inch or per-inch rate under its original test conditions.
FOAMULAR NGX XPS EPD · Table 3, NGX 250 U.S. rows; 250 data sheet p. 1 for test basis
Qualifying board 3.5 in · R-22 published
Documented sizes 0.5, 0.62, 0.75, 1, 1.2, 1.5, 1.55, 1.65, 2, 2.5, 3, 3.5, 4, 4.5 in
U.S. and Canada · U.S. thermal rows. ASTM C518 at 75°F · C1289 conditioning (90 days at 140°F)
Apparent conductivity 0.024 W/(m·K) · calculated from the reported nominal inch or per-inch rate under its original test conditions.
AP Foil-Faced Polyiso Continuous Insulation data sheet · p. 2, Table 1, U.S. board-only column and footnotes
Qualifying board 3.5 in · R-21.7 published
Documented sizes 1, 1.5, 2, 2.5, 3, 3.5 in
U.S. materials · confirm Canadian grade. ASTM C518 at 75°F under C1289 · aging duration unstated
Apparent conductivity 0.024 W/(m·K) · calculated from the reported nominal inch or per-inch rate under its original test conditions.
R2+ Matte coated-glass-faced polyiso data sheet · pp. 1 and 3, Thermal Resistance and Board Properties
Qualifying board No qualifying stock row documented.
Documented sizes 25–100 mm evaluated · stock steps unverified
U.S. listing · Canadian applicability unverified. CCRR-1066 Table 2 · R-6.8/in at 75°F · 25–100 mm
Apparent conductivity 0.021 W/(m·K) · calculated from the reported nominal inch or per-inch rate under its original test conditions.
Listing 39633 and CCRR-1066 Kooltherm insulation boards · CCRR-1066, Table 2
Targets use exact published rows, interpolation between rows or a documented per-inch rate within its cited range. The diamond marks the smallest documented board meeting the target. A range alone leaves stock thickness unresolved. Depth applies to the insulation layer. Whole-wall resistance, thermal bridging and code compliance require project-specific assembly review.
Look for product-specific ASTM E136 or CAN/ULC-S114 evidence.
Noncombustible insulation. 1 variants with relevant documentation. 4 unassessed.
Global Construction Network (GCN), operated by Nexus Pavilion Inc., provides informational research, product comparisons and decision support based on published manufacturer documentation and identified third-party sources.
Technical specifications and performance values attributed to manufacturers are manufacturer-reported. GCN does not independently test or certify products, guarantee their performance, or warrant the accuracy, completeness or currency of third-party information.
Search results, comparisons and screening outputs are intended to support preliminary research and do not constitute engineering advice, professional certification, regulatory approval or confirmation of project-specific suitability.
Users must independently verify current specifications, product configurations, manufacturer requirements and applicable regulations before making specification, purchasing or installation decisions.
Third-party intellectual property remains subject to its respective owners' rights. References to manufacturers and products do not imply endorsement, sponsorship or affiliation.
Use of GCN is subject to the applicable Nexus Pavilion Inc. Terms of Use.
Values retain their reported basis. Different test methods or conditions limit direct comparison.
Scroll across to compare all 5 insulation boards.
| Criterion | Mineral wool | XPS | Polyiso | Phenolic foam | |
|---|---|---|---|---|---|
| Comfortboard 80ROCKWOOL | FOAMULAR NGX 250Owens Corning | AP Foil-Faced Polyiso Continuous InsulationJohns Manville | R2+ Matte Coated-Glass-Faced PolyisoHenry / Carlisle CCW | Kooltherm K15 Rainscreen BoardKingspan Insulation | |
| Thermal performance | R-4.2/in at 75°F ASTM C518 (C177) Source DetailsR-4.2/in at 75°F Use U.S. units as printed for thickness estimates. The manufacturer’s product page gives a different metric RSI per inch from the linked sheet. Confirm the metric basis directly. Linked technical sheet · p. 2, Thermal Resistance | R-5.0 at 1 in · 75°F ASTM C518 · 180-day real-time aging Source DetailsR-5.0 at 1 in · 75°F At the same thickness the sheet lists R-5.4 at 40°F and R-5.6 at 25°F. CAN/ULC-S770-03 accelerated LTTR is a separate result of R-5.0 at 75°F. October 2025 · p. 1, Thermal Resistance and notes | R-6 at 1 in · R-26 at 4 in ASTM C518 · C1289 aged values Source DetailsR-6 at 1 in · R-26 at 4 in Use the published board-only column. Exclude the reflective air space and do not extrapolate a constant per-inch value. BID-0151 · 11/25 · p. 2, Tables 1–2 and footnote 1 | R-6.0 at 1 in · R-21.7 at 3.5 in ASTM C518 · 75°F · C1289 Source DetailsR-6.0 at 1 in · R-21.7 at 3.5 in CCW-3751 does not identify an aging duration or C1303 LTTR. No values assigned to unlisted special-order thicknesses. CCW-3751 · linked by Henry · pp. 1 and 3, Typical Properties and Packaging | R-6.8/in at 75°F CCRR-1066 · 25–100 mm Source DetailsR-6.8/in at 75°F Table 2 does not specify a thermal aging protocol or individual stock increments. No value derived outside the evaluated thickness range. March 2026 listing · February 2026 CCRR · CCRR-1066, §4.2 and Table 2 |
| Criterion | Mineral wool | XPS | Polyiso | Phenolic foam | |
|---|---|---|---|---|---|
| Comfortboard 80ROCKWOOL | FOAMULAR NGX 250Owens Corning | AP Foil-Faced Polyiso Continuous InsulationJohns Manville | R2+ Matte Coated-Glass-Faced PolyisoHenry / Carlisle CCW | Kooltherm K15 Rainscreen BoardKingspan Insulation | |
| Surface burning | 0 flame · 0 smoke ASTM E84 and CAN/ULC S102 Source Details0 flame · 0 smoke Surface indices characterize the test specimen. Linked technical sheet · p. 2, Reaction to Fire | 10 flame · 175 smoke ASTM E84 · UL U-197 reference Source Details10 flame · 175 smoke Confirm listed specimen thickness and certification conditions. October 2025 · p. 1, Physical Properties | ≤25 flame · ≤450 smoke ASTM E84 · 4 in foam core Source Details≤25 flame · ≤450 smoke The same sheet describes the board as combustible. Fire behavior depends on the wall assembly. BID-0151 · 11/25 · p. 2, Table 2 and Warning | <75 flame · <450 smoke ASTM E84 · foam core Source Details<75 flame · <450 smoke Applies to the standard Matte sheet linked by Henry. Class A is a separate published designation. CCW-3751 · linked by Henry · p. 1, Typical Properties | ≤25 flame · ≤450 smoke UL 723 / ASTM E84 · foil-facing listing Source Details≤25 flame · ≤450 smoke The listed exterior wall fire design names K122. Do not transfer its result to K15. March 2026 listing · February 2026 CCRR · Flame Spread Ratings, KIL/BI 30-02 item 9 |
| Noncombustibility | Noncombustible ASTM E136 and CAN/ULC S114 Source DetailsNoncombustible The findings apply to the insulation material. Verify fire requirements of the complete exterior wall. Linked technical sheet · p. 2, Reaction to Fire | Unassessed Comparable evidence unavailable | Combustible per manufacturer Product warning Source DetailsCombustible per manufacturer Coordinate any required thermal barrier. BID-0151 · 11/25 · p. 2, Warning | Unassessed Comparable evidence unavailable | Unassessed Comparable evidence unavailable |
| Exterior wall assembly evidence | Unassessed Comparable evidence unavailable | NFPA 285 wall reference Manufacturer wall example · U.S. Source DetailsNFPA 285 wall reference The CMU example names NGX 250 and notes performance for the specified component set. Obtain the exact tested construction and any permitted variations before relying on it. Enclosure Solutions · Overview and Products | NFPA 285 listed designs Intertek 29317 · U.S. Source DetailsNFPA 285 listed designs Check the individual JMC/FBI drawings for substrate, WRB, foam thickness, cladding, air cavity and openings. Confirm the current listing and project configuration. March 2025 revision · FIRE RATINGS and drawings 30-01 to 30-04 | NFPA 285 evaluation tables DrJ TER 1407-01 · U.S. Source DetailsNFPA 285 evaluation tables Table 7 permits up to 4 in of Matte with claddings 1–6 and a 2 in maximum air gap, or 3.5 in with claddings 7–17, a 1.5 in maximum gap and the specified opening detail. Match the base wall, cavity insulation, sheathing, WRB and cladding restrictions, including tighter drainage-mat limits. For NFPA 285-12 use Table 13 and its own component options. Applicability is assembly-specific. Report subject to renewal October 1, 2027. September 16, 2026 revision · subject to renewal October 1, 2027 · §2.1.3, Tables 7 and 11, Tables 13 and 17; pp. 18–20 and 33–35 | Exact K15 design unassessed KIL/BI 30-02 specifies K122 Source DetailsExact K15 design unassessed CCRR-1066 §6.4 calls for additional documentation for Types I–IV. Request an applicable K15 wall design and verify with the authority having jurisdiction. March 2026 listing · February 2026 CCRR · KIL/BI 30-02 item 9 and CCRR §6.4 |
| Criterion | Mineral wool | XPS | Polyiso | Phenolic foam | |
|---|---|---|---|---|---|
| Comfortboard 80ROCKWOOL | FOAMULAR NGX 250Owens Corning | AP Foil-Faced Polyiso Continuous InsulationJohns Manville | R2+ Matte Coated-Glass-Faced PolyisoHenry / Carlisle CCW | Kooltherm K15 Rainscreen BoardKingspan Insulation | |
| Vapor permeance | 31 US perms ASTM E96 · desiccant · unfaced Source Details31 US perms Product page does not identify specimen thickness. This value supports further investigation of vapor-open designs. Confirm permeance at project thickness. Current product page · Technical properties, Reaction to moisture | ≤1.5 US perms ASTM E96 · representative 1 in · unfaced Source Details≤1.5 US perms The procedure is unstated. Permeance decreases with thickness in the manufacturer’s notes. October 2025 · p. 1, Water Vapor Permeance | 0.05 US perms ASTM E96 · foil-faced · 1 in minimum Source Details0.05 US perms The manufacturer describes a Class I vapor retarder at 1 in. The sheet does not state the E96 procedure. BID-0151 · 11/25 · pp. 1–2, Vapor Barrier and Table 2 | <1 US perm ASTM E96 · 1 in coated-glass-faced board Source Details<1 US perm The source does not identify the E96 procedure. Do not substitute the foil-faced product’s result. CCW-3751 · linked by Henry · p. 1, Typical Properties | Unassessed Comparable evidence unavailable |
| Water absorption or sorption | 0.2 vol% sorption ASTM C1104 Source Details0.2 vol% sorption Water vapor sorption is a different endpoint from liquid water absorption. Keep the wall drained. Linked technical sheet · p. 2, Reaction to Moisture | ≤0.30 vol% ASTM C272 · maximum Source Details≤0.30 vol% The laboratory endpoint differs from C1763, C209 and vapor sorption. October 2025 · p. 1, Water Absorption | 0.1 vol% ASTM C1763 · procedure B Source Details0.1 vol% Water absorption and a wall’s water-resistive barrier role are separate properties. BID-0151 · 11/25 · p. 2, Table 2 | <0.1 vol% ASTM C209 Source Details<0.1 vol% The sheet limits ponding water exposure and prolonged direct sunlight exposure. CCW-3751 · linked by Henry · pp. 1–2, Typical Properties and Limitations | Unassessed Comparable evidence unavailable |
| Criterion | Mineral wool | XPS | Polyiso | Phenolic foam | |
|---|---|---|---|---|---|
| Comfortboard 80ROCKWOOL | FOAMULAR NGX 250Owens Corning | AP Foil-Faced Polyiso Continuous InsulationJohns Manville | R2+ Matte Coated-Glass-Faced PolyisoHenry / Carlisle CCW | Kooltherm K15 Rainscreen BoardKingspan Insulation | |
| Board sizes and availability | 1–5 in listed 24 × 48 in through 48 × 96 in Source Details1–5 in listed The linked sheet and product page show different size selections. Confirm a specific thickness and panel combination locally. Linked technical sheet · p. 2, Dimensions | ¾–4 in 24 or 48 in widths · 96 or 108 in lengths Source Details¾–4 in Check thickness and edge combinations in the packaging table. Do not apply these U.S. rows to C-200 or C-300. SCS-EPD-09753 · October 2026 · Tables 3 and 4, as delivered | 0.5–4.5 in 4 × 8, 9 or 10 ft Source Details0.5–4.5 in Consult the thickness-specific U.S. table. Verify Canadian order sizes and thermal data for the project. BID-0151 · 11/25 · p. 2, Table 1 | 1–3.5 in tabulated 16 or 24 in × 8 ft; 4 × 8 ft Source Details1–3.5 in tabulated Special-order 0.5–4.5 in range is documented. The thicker special-order range has no R-value table in the cited sheet. CCW-3751 · linked by Henry · p. 3, Packaging | 25–100 mm evaluated range Discrete stock sizes unverified Source Details25–100 mm evaluated range Confirm orderable dimensions and project-market availability with Kingspan. March 2026 listing · February 2026 CCRR · Listing information and CCRR Table 4 |
| Compressive resistance | 416 psf at 10% compression ASTM C165 · 2.89 psi converted Source Details416 psf at 10% compression Use the manufacturer-linked technical sheet. The product page shows 439 psf at 10%; reconcile values for attachment design. Linked technical sheet · p. 2, Compressive Resistance | ≥25 psi ASTM D1621 · yield or 10% deflection Source Details≥25 psi Whichever comes first. This grade property does not provide an allowable attachment or structural design load. October 2025 · p. 1, Compressive Strength and notes | ≥16 psi ASTM D1621 Source Details≥16 psi The 2025 sheet does not state the endpoint strain. AP Foil25 is a distinct product. BID-0151 · 11/25 · p. 2, Table 2 | 20 psi or 25 psi ASTM D1621 · grades 2 or 3 Source Details20 psi or 25 psi The base product has two distinct grades. Confirm the selected grade and the unreported test strain. CCW-3751 · linked by Henry · pp. 1 and 3, Typical Properties and Board Properties | Unassessed Comparable evidence unavailable |
| Dimensional stability | <0.5% linear shrinkage ASTM C356 · 1,200°F Source Details<0.5% linear shrinkage High-temperature shrinkage and ASTM D2126 conditioning are different tests. Linked technical sheet · p. 2, Dimensional Stability | ≤2% linear change ASTM D2126 Source Details≤2% linear change Use the product data sheet test basis. October 2025 · p. 1, Dimensional Stability | Unassessed Comparable evidence unavailable | 2% linear change ASTM D2126 · 7 days Source Details2% linear change Confirm conditioning details for any cross-product use. CCW-3751 · linked by Henry · p. 1, Typical Properties | Unassessed Comparable evidence unavailable |
| Board or core density | 8 lb/ft³ ASTM C303 · board density Source Details8 lb/ft³ The sheet gives 128 kg/m³. Linked technical sheet · p. 2, Density | ≥1.55 lb/ft³ ASTM D1622 · classification minimum Source Details≥1.55 lb/ft³ EPD Table 1 characterizes the U.S. grade. Actual product density may differ. SCS-EPD-09753 · October 2026 · Table 1, NGX 250 | Unassessed Comparable evidence unavailable | Unassessed Comparable evidence unavailable | 2.0 lb/ft³ nominal Phenolic core Source Details2.0 lb/ft³ nominal This is the listed nominal core density of K15, distinct from K100-series grades. March 2026 listing · February 2026 CCRR · Listing Information and CCRR §3.2 |
| Wall applications and attachment | Nonstructural exterior sheathing Rigid unfaced stone wool Source DetailsNonstructural exterior sheathing Coordinate the cladding support, fasteners, drainage and transitions for the full wall. Current product page · Product description | Cavity walls and exterior CMU Closed-cell Type IV XPS Source DetailsCavity walls and exterior CMU Use the assembly’s fasteners and liquid flashing where specified. Verify support behind the board. Enclosure Solutions · Wall overview and technical documents | Exterior wall sheathing Foil facers · stagger joints Source DetailsExterior wall sheathing Attachment and joint/penetration treatment depend on the assembly. The board is nonstructural. The sheet limits exposure to 60 days. BID-0151 · 11/25 · pp. 1–2, Installation and Limitations | Commercial above-grade exterior walls Capped screws, adhesive or both Source DetailsCommercial above-grade exterior walls Check the wall detail and local approval. Cladding attachment transfers loads through the board to the supporting wall. CCW-3751 · linked by Henry · pp. 1–3, Description, Installation and Fasteners | Rainscreen cladding Foil-faced nonstructural board Source DetailsRainscreen cladding The U.S. report requires a protected wall and disallows using the board as a siding nailing base. Fasteners must reach adequate backing. March 2026 listing · February 2026 CCRR · CCRR-1066 §§5.1, 6.2 and 6.3, Table 4 |
| Criterion | Mineral wool | XPS | Polyiso | Phenolic foam | |
|---|---|---|---|---|---|
| Comfortboard 80ROCKWOOL | FOAMULAR NGX 250Owens Corning | AP Foil-Faced Polyiso Continuous InsulationJohns Manville | R2+ Matte Coated-Glass-Faced PolyisoHenry / Carlisle CCW | Kooltherm K15 Rainscreen BoardKingspan Insulation | |
| Environmental declaration and GWP | 4.06 kg CO₂e A1–A3 · 1 m² at RSI 1 Source Details4.06 kg CO₂e North American lookup value scaled from the portfolio EPD reference product. Confirm the current declaration before reuse. v1.0 · July 2022 · p. 1, Comfortboard 80 lookup row | 7.08 kg CO₂e A1–A3 · IPCC AR6 · 1 m² at RSI 1 Source Details7.08 kg CO₂e North American NGX family result including 250, with use and end-of-life modules reported separately. This is not a 250-only result. SCS-EPD-09753 · October 2026 · Tables 8 and 20; product scope §2 | 2.88 kg CO₂e A1–A3 · TRACI 2.1 · 1 m² at RSI 1 Source Details2.88 kg CO₂e Production-weighted US/Canada polyiso sheathing family. A4, A5, C2 and C4 are reported separately. This is not an AP-only value. UL 4790545973.105.1 · EPD scope and Table 8 | Unassessed Comparable evidence unavailable | European EPD located Netherlands · 1 m² at 100 mm Source DetailsEuropean EPD located The cited EPD models Tiel production and a distinct European declared configuration. Its numeric impact is excluded from the North American comparison. EPD-KSI-20210047-CBA2-EN · General Information and Scope |
| Blowing agent | Unassessed Comparable evidence unavailable | HFC-134a eliminated NGX proprietary formulation Source DetailsHFC-134a eliminated This is a blowing-agent disclosure, separate from the board’s lifecycle GWP. SCS-EPD-09753 · October 2026 · §2.1, Product description | Hydrocarbon blend Cyclopentane and isopentane Source DetailsHydrocarbon blend Portfolio material composition. Do not use this to infer the whole board’s environmental impact. UL 4790545973.105.1 · Table 1, Average material composition | Unassessed Comparable evidence unavailable | Unassessed Comparable evidence unavailable |
Sources verified 2026-11-27. Each citation retains its regional scope and reported test basis.
ROCKWOOL · U.S. and Canada · North American sheet · Official product page
Use U.S. units as printed for thickness estimates. The manufacturer’s product page gives a different metric RSI per inch from the linked sheet. Confirm the metric basis directly.
Comfortboard 80 technical data sheet · p. 2, Thermal Resistance · Linked technical sheet · North America
The linked sheet and product page show different size selections. Confirm a specific thickness and panel combination locally.
Comfortboard 80 technical data sheet · p. 2, Dimensions · Linked technical sheet · North America
Surface indices characterize the test specimen.
Comfortboard 80 technical data sheet · p. 2, Reaction to Fire · Linked technical sheet · North America
The findings apply to the insulation material. Verify fire requirements of the complete exterior wall.
Comfortboard 80 technical data sheet · p. 2, Reaction to Fire · Linked technical sheet · North America
Product page does not identify specimen thickness. This value supports further investigation of vapor-open designs. Confirm permeance at project thickness.
Comfortboard 80 product information · Technical properties, Reaction to moisture · Current product page · North America
Water vapor sorption is a different endpoint from liquid water absorption. Keep the wall drained.
Comfortboard 80 technical data sheet · p. 2, Reaction to Moisture · Linked technical sheet · North America
Use the manufacturer-linked technical sheet. The product page shows 439 psf at 10%; reconcile values for attachment design.
Comfortboard 80 technical data sheet · p. 2, Compressive Resistance · Linked technical sheet · North America
High-temperature shrinkage and ASTM D2126 conditioning are different tests.
Comfortboard 80 technical data sheet · p. 2, Dimensional Stability · Linked technical sheet · North America
The sheet gives 128 kg/m³.
Comfortboard 80 technical data sheet · p. 2, Density · Linked technical sheet · North America
Coordinate the cladding support, fasteners, drainage and transitions for the full wall.
Comfortboard 80 product information · Product description · Current product page · North America
North American lookup value scaled from the portfolio EPD reference product. Confirm the current declaration before reuse.
EPD GWP lookup tables (original URL unavailable) · p. 1, Comfortboard 80 lookup row · v1.0 · July 2022 · North America
The 4.06 value comes from the July 2022 lookup bulletin. Its original download is unavailable. The later declaration has a different reporting basis. Manufacturer’s later stone wool EPD
Owens Corning · U.S. grade · Canadian C-series is separate · Official product page
At the same thickness the sheet lists R-5.4 at 40°F and R-5.6 at 25°F. CAN/ULC-S770-03 accelerated LTTR is a separate result of R-5.0 at 75°F.
FOAMULAR NGX 250 product data sheet · p. 1, Thermal Resistance and notes · October 2025 · United States
Check thickness and edge combinations in the packaging table. Do not apply these U.S. rows to C-200 or C-300.
FOAMULAR NGX XPS EPD · Tables 3 and 4, as delivered · SCS-EPD-09753 · October 2026 · United States and Canada
Confirm listed specimen thickness and certification conditions.
FOAMULAR NGX 250 product data sheet · p. 1, Physical Properties · October 2025 · United States
The CMU example names NGX 250 and notes performance for the specified component set. Obtain the exact tested construction and any permitted variations before relying on it.
CMU wall with concrete panel veneer and XPS CI (original URL unavailable) · Overview and Products · Enclosure Solutions · United States
Owens Corning moved the CMU wall example. The current page names NGX 250 and conditions the fire reference on the selected components. Current manufacturer page for this wall example
The procedure is unstated. Permeance decreases with thickness in the manufacturer’s notes.
FOAMULAR NGX 250 product data sheet · p. 1, Water Vapor Permeance · October 2025 · United States
The laboratory endpoint differs from C1763, C209 and vapor sorption.
FOAMULAR NGX 250 product data sheet · p. 1, Water Absorption · October 2025 · United States
Whichever comes first. This grade property does not provide an allowable attachment or structural design load.
FOAMULAR NGX 250 product data sheet · p. 1, Compressive Strength and notes · October 2025 · United States
Use the product data sheet test basis.
FOAMULAR NGX 250 product data sheet · p. 1, Dimensional Stability · October 2025 · United States
EPD Table 1 characterizes the U.S. grade. Actual product density may differ.
FOAMULAR NGX XPS EPD · Table 1, NGX 250 · SCS-EPD-09753 · October 2026 · United States and Canada
Use the assembly’s fasteners and liquid flashing where specified. Verify support behind the board.
CMU wall with concrete panel veneer and XPS CI (original URL unavailable) · Wall overview and technical documents · Enclosure Solutions · United States
Owens Corning moved the CMU wall example. The current page names NGX 250 and conditions the fire reference on the selected components. Current manufacturer page for this wall example
North American NGX family result including 250, with use and end-of-life modules reported separately. This is not a 250-only result.
FOAMULAR NGX XPS EPD · Tables 8 and 20; product scope §2 · SCS-EPD-09753 · October 2026 · United States and Canada
This is a blowing-agent disclosure, separate from the board’s lifecycle GWP.
FOAMULAR NGX XPS EPD · §2.1, Product description · SCS-EPD-09753 · October 2026 · United States and Canada
Johns Manville · U.S. and Canada · U.S. thermal rows · Official product page
Canadian product documentation
Use the published board-only column. Exclude the reflective air space and do not extrapolate a constant per-inch value.
AP Foil-Faced Polyiso Continuous Insulation data sheet · p. 2, Tables 1–2 and footnote 1 · BID-0151 · 11/25 · North America · U.S. R-value table
Consult the thickness-specific U.S. table. Verify Canadian order sizes and thermal data for the project.
AP Foil-Faced Polyiso Continuous Insulation data sheet · p. 2, Table 1 · BID-0151 · 11/25 · North America · U.S. R-value table
The same sheet describes the board as combustible. Fire behavior depends on the wall assembly.
AP Foil-Faced Polyiso Continuous Insulation data sheet · p. 2, Table 2 and Warning · BID-0151 · 11/25 · North America · U.S. R-value table
Coordinate any required thermal barrier.
AP Foil-Faced Polyiso Continuous Insulation data sheet · p. 2, Warning · BID-0151 · 11/25 · North America · U.S. R-value table
Check the individual JMC/FBI drawings for substrate, WRB, foam thickness, cladding, air cavity and openings. Confirm the current listing and project configuration.
Intertek listing 29317 and wall designs · FIRE RATINGS and drawings 30-01 to 30-04 · March 2025 revision · United States
The manufacturer describes a Class I vapor retarder at 1 in. The sheet does not state the E96 procedure.
AP Foil-Faced Polyiso Continuous Insulation data sheet · pp. 1–2, Vapor Barrier and Table 2 · BID-0151 · 11/25 · North America · U.S. R-value table
Water absorption and a wall’s water-resistive barrier role are separate properties.
AP Foil-Faced Polyiso Continuous Insulation data sheet · p. 2, Table 2 · BID-0151 · 11/25 · North America · U.S. R-value table
The 2025 sheet does not state the endpoint strain. AP Foil25 is a distinct product.
AP Foil-Faced Polyiso Continuous Insulation data sheet · p. 2, Table 2 · BID-0151 · 11/25 · North America · U.S. R-value table
Attachment and joint/penetration treatment depend on the assembly. The board is nonstructural. The sheet limits exposure to 60 days.
AP Foil-Faced Polyiso Continuous Insulation data sheet · pp. 1–2, Installation and Limitations · BID-0151 · 11/25 · North America · U.S. R-value table
Production-weighted US/Canada polyiso sheathing family. A4, A5, C2 and C4 are reported separately. This is not an AP-only value.
Polyisocyanurate sheathing EPD · EPD scope and Table 8 · UL 4790545973.105.1 · United States and Canada
Portfolio material composition. Do not use this to infer the whole board’s environmental impact.
Polyisocyanurate sheathing EPD · Table 1, Average material composition · UL 4790545973.105.1 · United States and Canada
Henry / Carlisle CCW · U.S. materials · confirm Canadian grade · Official product page
CCW-3751 does not identify an aging duration or C1303 LTTR. No values assigned to unlisted special-order thicknesses.
R2+ Matte coated-glass-faced polyiso data sheet · pp. 1 and 3, Typical Properties and Packaging · CCW-3751 · linked by Henry · United States
Special-order 0.5–4.5 in range is documented. The thicker special-order range has no R-value table in the cited sheet.
R2+ Matte coated-glass-faced polyiso data sheet · p. 3, Packaging · CCW-3751 · linked by Henry · United States
Applies to the standard Matte sheet linked by Henry. Class A is a separate published designation.
R2+ Matte coated-glass-faced polyiso data sheet · p. 1, Typical Properties · CCW-3751 · linked by Henry · United States
Table 7 permits up to 4 in of Matte with claddings 1–6 and a 2 in maximum air gap, or 3.5 in with claddings 7–17, a 1.5 in maximum gap and the specified opening detail. Match the base wall, cavity insulation, sheathing, WRB and cladding restrictions, including tighter drainage-mat limits. For NFPA 285-12 use Table 13 and its own component options. Applicability is assembly-specific. Report subject to renewal October 1, 2027.
TER 1407-01 R2+ wall assemblies · §2.1.3, Tables 7 and 11, Tables 13 and 17; pp. 18–20 and 33–35 · September 16, 2026 revision · subject to renewal October 1, 2027 · United States
The source does not identify the E96 procedure. Do not substitute the foil-faced product’s result.
R2+ Matte coated-glass-faced polyiso data sheet · p. 1, Typical Properties · CCW-3751 · linked by Henry · United States
The sheet limits ponding water exposure and prolonged direct sunlight exposure.
R2+ Matte coated-glass-faced polyiso data sheet · pp. 1–2, Typical Properties and Limitations · CCW-3751 · linked by Henry · United States
The base product has two distinct grades. Confirm the selected grade and the unreported test strain.
R2+ Matte coated-glass-faced polyiso data sheet · pp. 1 and 3, Typical Properties and Board Properties · CCW-3751 · linked by Henry · United States
Confirm conditioning details for any cross-product use.
R2+ Matte coated-glass-faced polyiso data sheet · p. 1, Typical Properties · CCW-3751 · linked by Henry · United States
Check the wall detail and local approval. Cladding attachment transfers loads through the board to the supporting wall.
R2+ Matte coated-glass-faced polyiso data sheet · pp. 1–3, Description, Installation and Fasteners · CCW-3751 · linked by Henry · United States
Kingspan Insulation · U.S. listing · Canadian applicability unverified · Official product page
Table 2 does not specify a thermal aging protocol or individual stock increments. No value derived outside the evaluated thickness range.
Listing 39633 and CCRR-1066 Kooltherm insulation boards · CCRR-1066, §4.2 and Table 2 · March 2026 listing · February 2026 CCRR · United States
Confirm orderable dimensions and project-market availability with Kingspan.
Listing 39633 and CCRR-1066 Kooltherm insulation boards · Listing information and CCRR Table 4 · March 2026 listing · February 2026 CCRR · United States
The listed exterior wall fire design names K122. Do not transfer its result to K15.
Listing 39633 and CCRR-1066 Kooltherm insulation boards · Flame Spread Ratings, KIL/BI 30-02 item 9 · March 2026 listing · February 2026 CCRR · United States
CCRR-1066 §6.4 calls for additional documentation for Types I–IV. Request an applicable K15 wall design and verify with the authority having jurisdiction.
Listing 39633 and CCRR-1066 Kooltherm insulation boards · KIL/BI 30-02 item 9 and CCRR §6.4 · March 2026 listing · February 2026 CCRR · United States
This is the listed nominal core density of K15, distinct from K100-series grades.
Listing 39633 and CCRR-1066 Kooltherm insulation boards · Listing Information and CCRR §3.2 · March 2026 listing · February 2026 CCRR · United States
The U.S. report requires a protected wall and disallows using the board as a siding nailing base. Fasteners must reach adequate backing.
Listing 39633 and CCRR-1066 Kooltherm insulation boards · CCRR-1066 §§5.1, 6.2 and 6.3, Table 4 · March 2026 listing · February 2026 CCRR · United States
The cited EPD models Tiel production and a distinct European declared configuration. Its numeric impact is excluded from the North American comparison.
Kooltherm K15 Tiel environmental product declaration (original URL unavailable) · General Information and Scope · EPD-KSI-20210047-CBA2-EN · Netherlands · excluded from North American comparison
The manufacturer’s original download is unavailable. This historical Tiel declaration expired March 23, 2026. Distributor-hosted copy of the IBU declaration
An unfaced stone wool board can support outward drying and may carry noncombustibility evidence. Lower R per inch can mean deeper cladding attachments. Check compression under the proposed attachment system.
Closed-cell extruded polystyrene can limit moisture uptake. Thickness, temperature and aging affect the documented thermal and vapor values. Keep foam surface-burning results separate from the wall assembly.
Faced polyisocyanurate can deliver high resistance in thinner sections. Foil and coated glass change vapor behavior, and aged board values vary with thickness. Coordinate facer and cladding with the wall detail.
A rigid thermoset core can provide high thermal resistance within a shallow cavity. Use the named product’s facer, evaluated thickness range and report. Exact-market moisture and mechanical evidence can be limited.
Review the jurisdiction’s adopted IBC, IECC, ASHRAE 90.1, or applicable Canadian code and energy requirements. Check thermal and fire performance at the whole-wall level. ASTM C1303 and CAN/ULC-S770 LTTR, C1289-conditioned results, and ASTM C518 or C177 test readings are separate reporting bases. The reviewed sources do not establish comparable ASTM C1303 or Canadian CAN/ULC-S134 results. Environmental values have different scope and methodology and are presented without ranking.