Nexus Pavilion · Decision Intelligence

Exterior Continuous Insulation

Compare insulation depth, fire evidence and moisture behavior across five exterior wall boards.

Above-grade walls · U.S. and Canadian evidence

Thermal thickness intelligence

Target insulation R-value
Products 5
Products to compare
3 Documented fit1 Exceeds limit1 Unresolved

Board thickness at R-20

Estimated targetPublished targetDocumented board4 in limit
Comfortboard 80ROCKWOOL · Mineral wool4.76 in estimated5 in boardExceeds limit

Qualifying board 5 in · R-21 calculated

Documented sizes 1, 1.25, 1.5, 2, 2.5, 3, 4, 5 in

U.S. and Canada · North American sheet. R-4.2/in at 75°F · ASTM C518 (C177), as reported

Apparent conductivity 0.034 W/(m·K) · calculated from the reported nominal inch or per-inch rate under its original test conditions.

Comfortboard 80 technical data sheet · p. 2, Thermal Resistance and Dimensions

FOAMULAR NGX 250Owens Corning · XPS4 in published4 in boardDocumented fit

Qualifying board 4 in · R-20 published

Documented sizes 0.75, 1, 1.5, 2, 2.5, 3, 4 in

U.S. grade · Canadian C-series is separate. U.S. thickness table · 180-day C518 basis at 75°F

Apparent conductivity 0.029 W/(m·K) · calculated from the reported nominal inch or per-inch rate under its original test conditions.

FOAMULAR NGX XPS EPD · Table 3, NGX 250 U.S. rows; 250 data sheet p. 1 for test basis

AP Foil-Faced Polyiso Continuous InsulationJohns Manville · Polyiso3.17 in estimated3.5 in boardDocumented fit

Qualifying board 3.5 in · R-22 published

Documented sizes 0.5, 0.62, 0.75, 1, 1.2, 1.5, 1.55, 1.65, 2, 2.5, 3, 3.5, 4, 4.5 in

U.S. and Canada · U.S. thermal rows. ASTM C518 at 75°F · C1289 conditioning (90 days at 140°F)

Apparent conductivity 0.024 W/(m·K) · calculated from the reported nominal inch or per-inch rate under its original test conditions.

AP Foil-Faced Polyiso Continuous Insulation data sheet · p. 2, Table 1, U.S. board-only column and footnotes

R2+ Matte Coated-Glass-Faced PolyisoHenry / Carlisle CCW · Polyiso3.23 in estimated3.5 in boardDocumented fit

Qualifying board 3.5 in · R-21.7 published

Documented sizes 1, 1.5, 2, 2.5, 3, 3.5 in

U.S. materials · confirm Canadian grade. ASTM C518 at 75°F under C1289 · aging duration unstated

Apparent conductivity 0.024 W/(m·K) · calculated from the reported nominal inch or per-inch rate under its original test conditions.

R2+ Matte coated-glass-faced polyiso data sheet · pp. 1 and 3, Thermal Resistance and Board Properties

Kooltherm K15 Rainscreen BoardKingspan Insulation · Phenolic foam2.94 in estimatedStock unverifiedUnresolved

Qualifying board No qualifying stock row documented.

Documented sizes 25–100 mm evaluated · stock steps unverified

U.S. listing · Canadian applicability unverified. CCRR-1066 Table 2 · R-6.8/in at 75°F · 25–100 mm

Apparent conductivity 0.021 W/(m·K) · calculated from the reported nominal inch or per-inch rate under its original test conditions.

Listing 39633 and CCRR-1066 Kooltherm insulation boards · CCRR-1066, Table 2

How thickness and depth fit are determined

Targets use exact published rows, interpolation between rows or a documented per-inch rate within its cited range. The diamond marks the smallest documented board meeting the target. A range alone leaves stock thickness unresolved. Depth applies to the insulation layer. Whole-wall resistance, thermal bridging and code compliance require project-specific assembly review.

Quick decision

Choose an application screen

Relevant evidence

1 of 5 variants

Look for product-specific ASTM E136 or CAN/ULC-S114 evidence.

Noncombustible insulation. 1 variants with relevant documentation. 4 unassessed.

Information & Decision Support Notice

Global Construction Network (GCN), operated by Nexus Pavilion Inc., provides informational research, product comparisons and decision support based on published manufacturer documentation and identified third-party sources.

Technical specifications and performance values attributed to manufacturers are manufacturer-reported. GCN does not independently test or certify products, guarantee their performance, or warrant the accuracy, completeness or currency of third-party information.

Search results, comparisons and screening outputs are intended to support preliminary research and do not constitute engineering advice, professional certification, regulatory approval or confirmation of project-specific suitability.

Users must independently verify current specifications, product configurations, manufacturer requirements and applicable regulations before making specification, purchasing or installation decisions.

Third-party intellectual property remains subject to its respective owners' rights. References to manufacturers and products do not imply endorsement, sponsorship or affiliation.

Use of GCN is subject to the applicable Nexus Pavilion Inc. Terms of Use.

Product comparison

Values retain their reported basis. Different test methods or conditions limit direct comparison.

Scroll across to compare all 5 insulation boards.

Thermal performance
Thermal performance — Exterior Continuous Insulation
CriterionMineral woolXPSPolyisoPhenolic foam
Comfortboard 80ROCKWOOLFOAMULAR NGX 250Owens CorningAP Foil-Faced Polyiso Continuous InsulationJohns ManvilleR2+ Matte Coated-Glass-Faced PolyisoHenry / Carlisle CCWKooltherm K15 Rainscreen BoardKingspan Insulation
Thermal performance

R-4.2/in at 75°F

ASTM C518 (C177)

Source
Details

R-4.2/in at 75°F

Use U.S. units as printed for thickness estimates. The manufacturer’s product page gives a different metric RSI per inch from the linked sheet. Confirm the metric basis directly.

Linked technical sheet · p. 2, Thermal Resistance

R-5.0 at 1 in · 75°F

ASTM C518 · 180-day real-time aging

Source
Details

R-5.0 at 1 in · 75°F

At the same thickness the sheet lists R-5.4 at 40°F and R-5.6 at 25°F. CAN/ULC-S770-03 accelerated LTTR is a separate result of R-5.0 at 75°F.

October 2025 · p. 1, Thermal Resistance and notes

R-6 at 1 in · R-26 at 4 in

ASTM C518 · C1289 aged values

Source
Details

R-6 at 1 in · R-26 at 4 in

Use the published board-only column. Exclude the reflective air space and do not extrapolate a constant per-inch value.

BID-0151 · 11/25 · p. 2, Tables 1–2 and footnote 1

R-6.0 at 1 in · R-21.7 at 3.5 in

ASTM C518 · 75°F · C1289

Source
Details

R-6.0 at 1 in · R-21.7 at 3.5 in

CCW-3751 does not identify an aging duration or C1303 LTTR. No values assigned to unlisted special-order thicknesses.

CCW-3751 · linked by Henry · pp. 1 and 3, Typical Properties and Packaging

R-6.8/in at 75°F

CCRR-1066 · 25–100 mm

Source
Details

R-6.8/in at 75°F

Table 2 does not specify a thermal aging protocol or individual stock increments. No value derived outside the evaluated thickness range.

March 2026 listing · February 2026 CCRR · CCRR-1066, §4.2 and Table 2

Fire performance
Fire performance — Exterior Continuous Insulation
CriterionMineral woolXPSPolyisoPhenolic foam
Comfortboard 80ROCKWOOLFOAMULAR NGX 250Owens CorningAP Foil-Faced Polyiso Continuous InsulationJohns ManvilleR2+ Matte Coated-Glass-Faced PolyisoHenry / Carlisle CCWKooltherm K15 Rainscreen BoardKingspan Insulation
Surface burning

0 flame · 0 smoke

ASTM E84 and CAN/ULC S102

Source
Details

0 flame · 0 smoke

Surface indices characterize the test specimen.

Linked technical sheet · p. 2, Reaction to Fire

10 flame · 175 smoke

ASTM E84 · UL U-197 reference

Source
Details

10 flame · 175 smoke

Confirm listed specimen thickness and certification conditions.

October 2025 · p. 1, Physical Properties

≤25 flame · ≤450 smoke

ASTM E84 · 4 in foam core

Source
Details

≤25 flame · ≤450 smoke

The same sheet describes the board as combustible. Fire behavior depends on the wall assembly.

BID-0151 · 11/25 · p. 2, Table 2 and Warning

<75 flame · <450 smoke

ASTM E84 · foam core

Source
Details

<75 flame · <450 smoke

Applies to the standard Matte sheet linked by Henry. Class A is a separate published designation.

CCW-3751 · linked by Henry · p. 1, Typical Properties

≤25 flame · ≤450 smoke

UL 723 / ASTM E84 · foil-facing listing

Source
Details

≤25 flame · ≤450 smoke

The listed exterior wall fire design names K122. Do not transfer its result to K15.

March 2026 listing · February 2026 CCRR · Flame Spread Ratings, KIL/BI 30-02 item 9

Noncombustibility

Noncombustible

ASTM E136 and CAN/ULC S114

Source
Details

Noncombustible

The findings apply to the insulation material. Verify fire requirements of the complete exterior wall.

Linked technical sheet · p. 2, Reaction to Fire

Unassessed

Comparable evidence unavailable

Combustible per manufacturer

Product warning

Source
Details

Combustible per manufacturer

Coordinate any required thermal barrier.

BID-0151 · 11/25 · p. 2, Warning

Unassessed

Comparable evidence unavailable

Unassessed

Comparable evidence unavailable

Exterior wall assembly evidence

Unassessed

Comparable evidence unavailable

NFPA 285 wall reference

Manufacturer wall example · U.S.

Source
Details

NFPA 285 wall reference

The CMU example names NGX 250 and notes performance for the specified component set. Obtain the exact tested construction and any permitted variations before relying on it.

Enclosure Solutions · Overview and Products

NFPA 285 listed designs

Intertek 29317 · U.S.

Source
Details

NFPA 285 listed designs

Check the individual JMC/FBI drawings for substrate, WRB, foam thickness, cladding, air cavity and openings. Confirm the current listing and project configuration.

March 2025 revision · FIRE RATINGS and drawings 30-01 to 30-04

NFPA 285 evaluation tables

DrJ TER 1407-01 · U.S.

Source
Details

NFPA 285 evaluation tables

Table 7 permits up to 4 in of Matte with claddings 1–6 and a 2 in maximum air gap, or 3.5 in with claddings 7–17, a 1.5 in maximum gap and the specified opening detail. Match the base wall, cavity insulation, sheathing, WRB and cladding restrictions, including tighter drainage-mat limits. For NFPA 285-12 use Table 13 and its own component options. Applicability is assembly-specific. Report subject to renewal October 1, 2027.

September 16, 2026 revision · subject to renewal October 1, 2027 · §2.1.3, Tables 7 and 11, Tables 13 and 17; pp. 18–20 and 33–35

Exact K15 design unassessed

KIL/BI 30-02 specifies K122

Source
Details

Exact K15 design unassessed

CCRR-1066 §6.4 calls for additional documentation for Types I–IV. Request an applicable K15 wall design and verify with the authority having jurisdiction.

March 2026 listing · February 2026 CCRR · KIL/BI 30-02 item 9 and CCRR §6.4

Moisture and vapor
Moisture and vapor — Exterior Continuous Insulation
CriterionMineral woolXPSPolyisoPhenolic foam
Comfortboard 80ROCKWOOLFOAMULAR NGX 250Owens CorningAP Foil-Faced Polyiso Continuous InsulationJohns ManvilleR2+ Matte Coated-Glass-Faced PolyisoHenry / Carlisle CCWKooltherm K15 Rainscreen BoardKingspan Insulation
Vapor permeance

31 US perms

ASTM E96 · desiccant · unfaced

Source
Details

31 US perms

Product page does not identify specimen thickness. This value supports further investigation of vapor-open designs. Confirm permeance at project thickness.

Current product page · Technical properties, Reaction to moisture

≤1.5 US perms

ASTM E96 · representative 1 in · unfaced

Source
Details

≤1.5 US perms

The procedure is unstated. Permeance decreases with thickness in the manufacturer’s notes.

October 2025 · p. 1, Water Vapor Permeance

0.05 US perms

ASTM E96 · foil-faced · 1 in minimum

Source
Details

0.05 US perms

The manufacturer describes a Class I vapor retarder at 1 in. The sheet does not state the E96 procedure.

BID-0151 · 11/25 · pp. 1–2, Vapor Barrier and Table 2

<1 US perm

ASTM E96 · 1 in coated-glass-faced board

Source
Details

<1 US perm

The source does not identify the E96 procedure. Do not substitute the foil-faced product’s result.

CCW-3751 · linked by Henry · p. 1, Typical Properties

Unassessed

Comparable evidence unavailable

Water absorption or sorption

0.2 vol% sorption

ASTM C1104

Source
Details

0.2 vol% sorption

Water vapor sorption is a different endpoint from liquid water absorption. Keep the wall drained.

Linked technical sheet · p. 2, Reaction to Moisture

≤0.30 vol%

ASTM C272 · maximum

Source
Details

≤0.30 vol%

The laboratory endpoint differs from C1763, C209 and vapor sorption.

October 2025 · p. 1, Water Absorption

0.1 vol%

ASTM C1763 · procedure B

Source
Details

0.1 vol%

Water absorption and a wall’s water-resistive barrier role are separate properties.

BID-0151 · 11/25 · p. 2, Table 2

<0.1 vol%

ASTM C209

Source
Details

<0.1 vol%

The sheet limits ponding water exposure and prolonged direct sunlight exposure.

CCW-3751 · linked by Henry · pp. 1–2, Typical Properties and Limitations

Unassessed

Comparable evidence unavailable

Mechanical and installation
Mechanical and installation — Exterior Continuous Insulation
CriterionMineral woolXPSPolyisoPhenolic foam
Comfortboard 80ROCKWOOLFOAMULAR NGX 250Owens CorningAP Foil-Faced Polyiso Continuous InsulationJohns ManvilleR2+ Matte Coated-Glass-Faced PolyisoHenry / Carlisle CCWKooltherm K15 Rainscreen BoardKingspan Insulation
Board sizes and availability

1–5 in listed

24 × 48 in through 48 × 96 in

Source
Details

1–5 in listed

The linked sheet and product page show different size selections. Confirm a specific thickness and panel combination locally.

Linked technical sheet · p. 2, Dimensions

¾–4 in

24 or 48 in widths · 96 or 108 in lengths

Source
Details

¾–4 in

Check thickness and edge combinations in the packaging table. Do not apply these U.S. rows to C-200 or C-300.

SCS-EPD-09753 · October 2026 · Tables 3 and 4, as delivered

0.5–4.5 in

4 × 8, 9 or 10 ft

Source
Details

0.5–4.5 in

Consult the thickness-specific U.S. table. Verify Canadian order sizes and thermal data for the project.

BID-0151 · 11/25 · p. 2, Table 1

1–3.5 in tabulated

16 or 24 in × 8 ft; 4 × 8 ft

Source
Details

1–3.5 in tabulated

Special-order 0.5–4.5 in range is documented. The thicker special-order range has no R-value table in the cited sheet.

CCW-3751 · linked by Henry · p. 3, Packaging

25–100 mm evaluated range

Discrete stock sizes unverified

Source
Details

25–100 mm evaluated range

Confirm orderable dimensions and project-market availability with Kingspan.

March 2026 listing · February 2026 CCRR · Listing information and CCRR Table 4

Compressive resistance

416 psf at 10% compression

ASTM C165 · 2.89 psi converted

Source
Details

416 psf at 10% compression

Use the manufacturer-linked technical sheet. The product page shows 439 psf at 10%; reconcile values for attachment design.

Linked technical sheet · p. 2, Compressive Resistance

≥25 psi

ASTM D1621 · yield or 10% deflection

Source
Details

≥25 psi

Whichever comes first. This grade property does not provide an allowable attachment or structural design load.

October 2025 · p. 1, Compressive Strength and notes

≥16 psi

ASTM D1621

Source
Details

≥16 psi

The 2025 sheet does not state the endpoint strain. AP Foil25 is a distinct product.

BID-0151 · 11/25 · p. 2, Table 2

20 psi or 25 psi

ASTM D1621 · grades 2 or 3

Source
Details

20 psi or 25 psi

The base product has two distinct grades. Confirm the selected grade and the unreported test strain.

CCW-3751 · linked by Henry · pp. 1 and 3, Typical Properties and Board Properties

Unassessed

Comparable evidence unavailable

Dimensional stability

<0.5% linear shrinkage

ASTM C356 · 1,200°F

Source
Details

<0.5% linear shrinkage

High-temperature shrinkage and ASTM D2126 conditioning are different tests.

Linked technical sheet · p. 2, Dimensional Stability

≤2% linear change

ASTM D2126

Source
Details

≤2% linear change

Use the product data sheet test basis.

October 2025 · p. 1, Dimensional Stability

Unassessed

Comparable evidence unavailable

2% linear change

ASTM D2126 · 7 days

Source
Details

2% linear change

Confirm conditioning details for any cross-product use.

CCW-3751 · linked by Henry · p. 1, Typical Properties

Unassessed

Comparable evidence unavailable

Board or core density

8 lb/ft³

ASTM C303 · board density

Source
Details

8 lb/ft³

The sheet gives 128 kg/m³.

Linked technical sheet · p. 2, Density

≥1.55 lb/ft³

ASTM D1622 · classification minimum

Source
Details

≥1.55 lb/ft³

EPD Table 1 characterizes the U.S. grade. Actual product density may differ.

SCS-EPD-09753 · October 2026 · Table 1, NGX 250

Unassessed

Comparable evidence unavailable

Unassessed

Comparable evidence unavailable

2.0 lb/ft³ nominal

Phenolic core

Source
Details

2.0 lb/ft³ nominal

This is the listed nominal core density of K15, distinct from K100-series grades.

March 2026 listing · February 2026 CCRR · Listing Information and CCRR §3.2

Wall applications and attachment

Nonstructural exterior sheathing

Rigid unfaced stone wool

Source
Details

Nonstructural exterior sheathing

Coordinate the cladding support, fasteners, drainage and transitions for the full wall.

Current product page · Product description

Cavity walls and exterior CMU

Closed-cell Type IV XPS

Source
Details

Cavity walls and exterior CMU

Use the assembly’s fasteners and liquid flashing where specified. Verify support behind the board.

Enclosure Solutions · Wall overview and technical documents

Exterior wall sheathing

Foil facers · stagger joints

Source
Details

Exterior wall sheathing

Attachment and joint/penetration treatment depend on the assembly. The board is nonstructural. The sheet limits exposure to 60 days.

BID-0151 · 11/25 · pp. 1–2, Installation and Limitations

Commercial above-grade exterior walls

Capped screws, adhesive or both

Source
Details

Commercial above-grade exterior walls

Check the wall detail and local approval. Cladding attachment transfers loads through the board to the supporting wall.

CCW-3751 · linked by Henry · pp. 1–3, Description, Installation and Fasteners

Rainscreen cladding

Foil-faced nonstructural board

Source
Details

Rainscreen cladding

The U.S. report requires a protected wall and disallows using the board as a siding nailing base. Fasteners must reach adequate backing.

March 2026 listing · February 2026 CCRR · CCRR-1066 §§5.1, 6.2 and 6.3, Table 4

Environmental performance
Environmental performance — Exterior Continuous Insulation
CriterionMineral woolXPSPolyisoPhenolic foam
Comfortboard 80ROCKWOOLFOAMULAR NGX 250Owens CorningAP Foil-Faced Polyiso Continuous InsulationJohns ManvilleR2+ Matte Coated-Glass-Faced PolyisoHenry / Carlisle CCWKooltherm K15 Rainscreen BoardKingspan Insulation
Environmental declaration and GWP

4.06 kg CO₂e

A1–A3 · 1 m² at RSI 1

Source
Details

4.06 kg CO₂e

North American lookup value scaled from the portfolio EPD reference product. Confirm the current declaration before reuse.

v1.0 · July 2022 · p. 1, Comfortboard 80 lookup row

7.08 kg CO₂e

A1–A3 · IPCC AR6 · 1 m² at RSI 1

Source
Details

7.08 kg CO₂e

North American NGX family result including 250, with use and end-of-life modules reported separately. This is not a 250-only result.

SCS-EPD-09753 · October 2026 · Tables 8 and 20; product scope §2

2.88 kg CO₂e

A1–A3 · TRACI 2.1 · 1 m² at RSI 1

Source
Details

2.88 kg CO₂e

Production-weighted US/Canada polyiso sheathing family. A4, A5, C2 and C4 are reported separately. This is not an AP-only value.

UL 4790545973.105.1 · EPD scope and Table 8

Unassessed

Comparable evidence unavailable

European EPD located

Netherlands · 1 m² at 100 mm

Source
Details

European EPD located

The cited EPD models Tiel production and a distinct European declared configuration. Its numeric impact is excluded from the North American comparison.

EPD-KSI-20210047-CBA2-EN · General Information and Scope

Blowing agent

Unassessed

Comparable evidence unavailable

HFC-134a eliminated

NGX proprietary formulation

Source
Details

HFC-134a eliminated

This is a blowing-agent disclosure, separate from the board’s lifecycle GWP.

SCS-EPD-09753 · October 2026 · §2.1, Product description

Hydrocarbon blend

Cyclopentane and isopentane

Source
Details

Hydrocarbon blend

Portfolio material composition. Do not use this to infer the whole board’s environmental impact.

UL 4790545973.105.1 · Table 1, Average material composition

Unassessed

Comparable evidence unavailable

Unassessed

Comparable evidence unavailable

Technical evidence

Sources verified 2026-11-27. Each citation retains its regional scope and reported test basis.

Comfortboard 80ROCKWOOL · Mineral wool

ROCKWOOL · U.S. and Canada · North American sheet · Official product page

Thermal performance
R-4.2/in at 75°F · ASTM C518 (C177)

Use U.S. units as printed for thickness estimates. The manufacturer’s product page gives a different metric RSI per inch from the linked sheet. Confirm the metric basis directly.

Comfortboard 80 technical data sheet · p. 2, Thermal Resistance · Linked technical sheet · North America

Board sizes and availability
1–5 in listed · 24 × 48 in through 48 × 96 in

The linked sheet and product page show different size selections. Confirm a specific thickness and panel combination locally.

Comfortboard 80 technical data sheet · p. 2, Dimensions · Linked technical sheet · North America

Surface burning
0 flame · 0 smoke · ASTM E84 and CAN/ULC S102

Surface indices characterize the test specimen.

Comfortboard 80 technical data sheet · p. 2, Reaction to Fire · Linked technical sheet · North America

Noncombustibility
Noncombustible · ASTM E136 and CAN/ULC S114

The findings apply to the insulation material. Verify fire requirements of the complete exterior wall.

Comfortboard 80 technical data sheet · p. 2, Reaction to Fire · Linked technical sheet · North America

Exterior wall assembly evidence
Unassessed in the reviewed sources.
Vapor permeance
31 US perms · ASTM E96 · desiccant · unfaced

Product page does not identify specimen thickness. This value supports further investigation of vapor-open designs. Confirm permeance at project thickness.

Comfortboard 80 product information · Technical properties, Reaction to moisture · Current product page · North America

Water absorption or sorption
0.2 vol% sorption · ASTM C1104

Water vapor sorption is a different endpoint from liquid water absorption. Keep the wall drained.

Comfortboard 80 technical data sheet · p. 2, Reaction to Moisture · Linked technical sheet · North America

Compressive resistance
416 psf at 10% compression · ASTM C165 · 2.89 psi converted

Use the manufacturer-linked technical sheet. The product page shows 439 psf at 10%; reconcile values for attachment design.

Comfortboard 80 technical data sheet · p. 2, Compressive Resistance · Linked technical sheet · North America

Dimensional stability
<0.5% linear shrinkage · ASTM C356 · 1,200°F

High-temperature shrinkage and ASTM D2126 conditioning are different tests.

Comfortboard 80 technical data sheet · p. 2, Dimensional Stability · Linked technical sheet · North America

Board or core density
8 lb/ft³ · ASTM C303 · board density

The sheet gives 128 kg/m³.

Comfortboard 80 technical data sheet · p. 2, Density · Linked technical sheet · North America

Wall applications and attachment
Nonstructural exterior sheathing · Rigid unfaced stone wool

Coordinate the cladding support, fasteners, drainage and transitions for the full wall.

Comfortboard 80 product information · Product description · Current product page · North America

Environmental declaration and GWP
4.06 kg CO₂e · A1–A3 · 1 m² at RSI 1

North American lookup value scaled from the portfolio EPD reference product. Confirm the current declaration before reuse.

EPD GWP lookup tables (original URL unavailable) · p. 1, Comfortboard 80 lookup row · v1.0 · July 2022 · North America

The 4.06 value comes from the July 2022 lookup bulletin. Its original download is unavailable. The later declaration has a different reporting basis. Manufacturer’s later stone wool EPD

Blowing agent
Unassessed in the reviewed sources.
FOAMULAR NGX 250Owens Corning · XPS

Owens Corning · U.S. grade · Canadian C-series is separate · Official product page

Thermal performance
R-5.0 at 1 in · 75°F · ASTM C518 · 180-day real-time aging

At the same thickness the sheet lists R-5.4 at 40°F and R-5.6 at 25°F. CAN/ULC-S770-03 accelerated LTTR is a separate result of R-5.0 at 75°F.

FOAMULAR NGX 250 product data sheet · p. 1, Thermal Resistance and notes · October 2025 · United States

Board sizes and availability
¾–4 in · 24 or 48 in widths · 96 or 108 in lengths

Check thickness and edge combinations in the packaging table. Do not apply these U.S. rows to C-200 or C-300.

FOAMULAR NGX XPS EPD · Tables 3 and 4, as delivered · SCS-EPD-09753 · October 2026 · United States and Canada

Surface burning
10 flame · 175 smoke · ASTM E84 · UL U-197 reference

Confirm listed specimen thickness and certification conditions.

FOAMULAR NGX 250 product data sheet · p. 1, Physical Properties · October 2025 · United States

Noncombustibility
Unassessed in the reviewed sources.
Exterior wall assembly evidence
NFPA 285 wall reference · Manufacturer wall example · U.S.

The CMU example names NGX 250 and notes performance for the specified component set. Obtain the exact tested construction and any permitted variations before relying on it.

CMU wall with concrete panel veneer and XPS CI (original URL unavailable) · Overview and Products · Enclosure Solutions · United States

Owens Corning moved the CMU wall example. The current page names NGX 250 and conditions the fire reference on the selected components. Current manufacturer page for this wall example

Vapor permeance
≤1.5 US perms · ASTM E96 · representative 1 in · unfaced

The procedure is unstated. Permeance decreases with thickness in the manufacturer’s notes.

FOAMULAR NGX 250 product data sheet · p. 1, Water Vapor Permeance · October 2025 · United States

Water absorption or sorption
≤0.30 vol% · ASTM C272 · maximum

The laboratory endpoint differs from C1763, C209 and vapor sorption.

FOAMULAR NGX 250 product data sheet · p. 1, Water Absorption · October 2025 · United States

Compressive resistance
≥25 psi · ASTM D1621 · yield or 10% deflection

Whichever comes first. This grade property does not provide an allowable attachment or structural design load.

FOAMULAR NGX 250 product data sheet · p. 1, Compressive Strength and notes · October 2025 · United States

Dimensional stability
≤2% linear change · ASTM D2126

Use the product data sheet test basis.

FOAMULAR NGX 250 product data sheet · p. 1, Dimensional Stability · October 2025 · United States

Board or core density
≥1.55 lb/ft³ · ASTM D1622 · classification minimum

EPD Table 1 characterizes the U.S. grade. Actual product density may differ.

FOAMULAR NGX XPS EPD · Table 1, NGX 250 · SCS-EPD-09753 · October 2026 · United States and Canada

Wall applications and attachment
Cavity walls and exterior CMU · Closed-cell Type IV XPS

Use the assembly’s fasteners and liquid flashing where specified. Verify support behind the board.

CMU wall with concrete panel veneer and XPS CI (original URL unavailable) · Wall overview and technical documents · Enclosure Solutions · United States

Owens Corning moved the CMU wall example. The current page names NGX 250 and conditions the fire reference on the selected components. Current manufacturer page for this wall example

Environmental declaration and GWP
7.08 kg CO₂e · A1–A3 · IPCC AR6 · 1 m² at RSI 1

North American NGX family result including 250, with use and end-of-life modules reported separately. This is not a 250-only result.

FOAMULAR NGX XPS EPD · Tables 8 and 20; product scope §2 · SCS-EPD-09753 · October 2026 · United States and Canada

Blowing agent
HFC-134a eliminated · NGX proprietary formulation

This is a blowing-agent disclosure, separate from the board’s lifecycle GWP.

FOAMULAR NGX XPS EPD · §2.1, Product description · SCS-EPD-09753 · October 2026 · United States and Canada

AP Foil-Faced Polyiso Continuous InsulationJohns Manville · Polyiso

Johns Manville · U.S. and Canada · U.S. thermal rows · Official product page

Canadian product documentation

Thermal performance
R-6 at 1 in · R-26 at 4 in · ASTM C518 · C1289 aged values

Use the published board-only column. Exclude the reflective air space and do not extrapolate a constant per-inch value.

AP Foil-Faced Polyiso Continuous Insulation data sheet · p. 2, Tables 1–2 and footnote 1 · BID-0151 · 11/25 · North America · U.S. R-value table

Board sizes and availability
0.5–4.5 in · 4 × 8, 9 or 10 ft

Consult the thickness-specific U.S. table. Verify Canadian order sizes and thermal data for the project.

AP Foil-Faced Polyiso Continuous Insulation data sheet · p. 2, Table 1 · BID-0151 · 11/25 · North America · U.S. R-value table

Surface burning
≤25 flame · ≤450 smoke · ASTM E84 · 4 in foam core

The same sheet describes the board as combustible. Fire behavior depends on the wall assembly.

AP Foil-Faced Polyiso Continuous Insulation data sheet · p. 2, Table 2 and Warning · BID-0151 · 11/25 · North America · U.S. R-value table

Noncombustibility
Combustible per manufacturer · Product warning

Coordinate any required thermal barrier.

AP Foil-Faced Polyiso Continuous Insulation data sheet · p. 2, Warning · BID-0151 · 11/25 · North America · U.S. R-value table

Exterior wall assembly evidence
NFPA 285 listed designs · Intertek 29317 · U.S.

Check the individual JMC/FBI drawings for substrate, WRB, foam thickness, cladding, air cavity and openings. Confirm the current listing and project configuration.

Intertek listing 29317 and wall designs · FIRE RATINGS and drawings 30-01 to 30-04 · March 2025 revision · United States

Vapor permeance
0.05 US perms · ASTM E96 · foil-faced · 1 in minimum

The manufacturer describes a Class I vapor retarder at 1 in. The sheet does not state the E96 procedure.

AP Foil-Faced Polyiso Continuous Insulation data sheet · pp. 1–2, Vapor Barrier and Table 2 · BID-0151 · 11/25 · North America · U.S. R-value table

Water absorption or sorption
0.1 vol% · ASTM C1763 · procedure B

Water absorption and a wall’s water-resistive barrier role are separate properties.

AP Foil-Faced Polyiso Continuous Insulation data sheet · p. 2, Table 2 · BID-0151 · 11/25 · North America · U.S. R-value table

Compressive resistance
≥16 psi · ASTM D1621

The 2025 sheet does not state the endpoint strain. AP Foil25 is a distinct product.

AP Foil-Faced Polyiso Continuous Insulation data sheet · p. 2, Table 2 · BID-0151 · 11/25 · North America · U.S. R-value table

Dimensional stability
Unassessed in the reviewed sources.
Board or core density
Unassessed in the reviewed sources.
Wall applications and attachment
Exterior wall sheathing · Foil facers · stagger joints

Attachment and joint/penetration treatment depend on the assembly. The board is nonstructural. The sheet limits exposure to 60 days.

AP Foil-Faced Polyiso Continuous Insulation data sheet · pp. 1–2, Installation and Limitations · BID-0151 · 11/25 · North America · U.S. R-value table

Environmental declaration and GWP
2.88 kg CO₂e · A1–A3 · TRACI 2.1 · 1 m² at RSI 1

Production-weighted US/Canada polyiso sheathing family. A4, A5, C2 and C4 are reported separately. This is not an AP-only value.

Polyisocyanurate sheathing EPD · EPD scope and Table 8 · UL 4790545973.105.1 · United States and Canada

Blowing agent
Hydrocarbon blend · Cyclopentane and isopentane

Portfolio material composition. Do not use this to infer the whole board’s environmental impact.

Polyisocyanurate sheathing EPD · Table 1, Average material composition · UL 4790545973.105.1 · United States and Canada

R2+ Matte Coated-Glass-Faced PolyisoHenry / Carlisle CCW · Polyiso

Henry / Carlisle CCW · U.S. materials · confirm Canadian grade · Official product page

Thermal performance
R-6.0 at 1 in · R-21.7 at 3.5 in · ASTM C518 · 75°F · C1289

CCW-3751 does not identify an aging duration or C1303 LTTR. No values assigned to unlisted special-order thicknesses.

R2+ Matte coated-glass-faced polyiso data sheet · pp. 1 and 3, Typical Properties and Packaging · CCW-3751 · linked by Henry · United States

Board sizes and availability
1–3.5 in tabulated · 16 or 24 in × 8 ft; 4 × 8 ft

Special-order 0.5–4.5 in range is documented. The thicker special-order range has no R-value table in the cited sheet.

R2+ Matte coated-glass-faced polyiso data sheet · p. 3, Packaging · CCW-3751 · linked by Henry · United States

Surface burning
<75 flame · <450 smoke · ASTM E84 · foam core

Applies to the standard Matte sheet linked by Henry. Class A is a separate published designation.

R2+ Matte coated-glass-faced polyiso data sheet · p. 1, Typical Properties · CCW-3751 · linked by Henry · United States

Noncombustibility
Unassessed in the reviewed sources.
Exterior wall assembly evidence
NFPA 285 evaluation tables · DrJ TER 1407-01 · U.S.

Table 7 permits up to 4 in of Matte with claddings 1–6 and a 2 in maximum air gap, or 3.5 in with claddings 7–17, a 1.5 in maximum gap and the specified opening detail. Match the base wall, cavity insulation, sheathing, WRB and cladding restrictions, including tighter drainage-mat limits. For NFPA 285-12 use Table 13 and its own component options. Applicability is assembly-specific. Report subject to renewal October 1, 2027.

TER 1407-01 R2+ wall assemblies · §2.1.3, Tables 7 and 11, Tables 13 and 17; pp. 18–20 and 33–35 · September 16, 2026 revision · subject to renewal October 1, 2027 · United States

Vapor permeance
<1 US perm · ASTM E96 · 1 in coated-glass-faced board

The source does not identify the E96 procedure. Do not substitute the foil-faced product’s result.

R2+ Matte coated-glass-faced polyiso data sheet · p. 1, Typical Properties · CCW-3751 · linked by Henry · United States

Water absorption or sorption
<0.1 vol% · ASTM C209

The sheet limits ponding water exposure and prolonged direct sunlight exposure.

R2+ Matte coated-glass-faced polyiso data sheet · pp. 1–2, Typical Properties and Limitations · CCW-3751 · linked by Henry · United States

Compressive resistance
20 psi or 25 psi · ASTM D1621 · grades 2 or 3

The base product has two distinct grades. Confirm the selected grade and the unreported test strain.

R2+ Matte coated-glass-faced polyiso data sheet · pp. 1 and 3, Typical Properties and Board Properties · CCW-3751 · linked by Henry · United States

Dimensional stability
2% linear change · ASTM D2126 · 7 days

Confirm conditioning details for any cross-product use.

R2+ Matte coated-glass-faced polyiso data sheet · p. 1, Typical Properties · CCW-3751 · linked by Henry · United States

Board or core density
Unassessed in the reviewed sources.
Wall applications and attachment
Commercial above-grade exterior walls · Capped screws, adhesive or both

Check the wall detail and local approval. Cladding attachment transfers loads through the board to the supporting wall.

R2+ Matte coated-glass-faced polyiso data sheet · pp. 1–3, Description, Installation and Fasteners · CCW-3751 · linked by Henry · United States

Environmental declaration and GWP
Unassessed in the reviewed sources.
Blowing agent
Unassessed in the reviewed sources.
Kooltherm K15 Rainscreen BoardKingspan Insulation · Phenolic foam

Kingspan Insulation · U.S. listing · Canadian applicability unverified · Official product page

Thermal performance
R-6.8/in at 75°F · CCRR-1066 · 25–100 mm

Table 2 does not specify a thermal aging protocol or individual stock increments. No value derived outside the evaluated thickness range.

Listing 39633 and CCRR-1066 Kooltherm insulation boards · CCRR-1066, §4.2 and Table 2 · March 2026 listing · February 2026 CCRR · United States

Board sizes and availability
25–100 mm evaluated range · Discrete stock sizes unverified

Confirm orderable dimensions and project-market availability with Kingspan.

Listing 39633 and CCRR-1066 Kooltherm insulation boards · Listing information and CCRR Table 4 · March 2026 listing · February 2026 CCRR · United States

Surface burning
≤25 flame · ≤450 smoke · UL 723 / ASTM E84 · foil-facing listing

The listed exterior wall fire design names K122. Do not transfer its result to K15.

Listing 39633 and CCRR-1066 Kooltherm insulation boards · Flame Spread Ratings, KIL/BI 30-02 item 9 · March 2026 listing · February 2026 CCRR · United States

Noncombustibility
Unassessed in the reviewed sources.
Exterior wall assembly evidence
Exact K15 design unassessed · KIL/BI 30-02 specifies K122

CCRR-1066 §6.4 calls for additional documentation for Types I–IV. Request an applicable K15 wall design and verify with the authority having jurisdiction.

Listing 39633 and CCRR-1066 Kooltherm insulation boards · KIL/BI 30-02 item 9 and CCRR §6.4 · March 2026 listing · February 2026 CCRR · United States

Vapor permeance
Unassessed in the reviewed sources.
Water absorption or sorption
Unassessed in the reviewed sources.
Compressive resistance
Unassessed in the reviewed sources.
Dimensional stability
Unassessed in the reviewed sources.
Board or core density
2.0 lb/ft³ nominal · Phenolic core

This is the listed nominal core density of K15, distinct from K100-series grades.

Listing 39633 and CCRR-1066 Kooltherm insulation boards · Listing Information and CCRR §3.2 · March 2026 listing · February 2026 CCRR · United States

Wall applications and attachment
Rainscreen cladding · Foil-faced nonstructural board

The U.S. report requires a protected wall and disallows using the board as a siding nailing base. Fasteners must reach adequate backing.

Listing 39633 and CCRR-1066 Kooltherm insulation boards · CCRR-1066 §§5.1, 6.2 and 6.3, Table 4 · March 2026 listing · February 2026 CCRR · United States

Environmental declaration and GWP
European EPD located · Netherlands · 1 m² at 100 mm

The cited EPD models Tiel production and a distinct European declared configuration. Its numeric impact is excluded from the North American comparison.

Kooltherm K15 Tiel environmental product declaration (original URL unavailable) · General Information and Scope · EPD-KSI-20210047-CBA2-EN · Netherlands · excluded from North American comparison

The manufacturer’s original download is unavailable. This historical Tiel declaration expired March 23, 2026. Distributor-hosted copy of the IBU declaration

Blowing agent
Unassessed in the reviewed sources.

Material families

Mineral wool

An unfaced stone wool board can support outward drying and may carry noncombustibility evidence. Lower R per inch can mean deeper cladding attachments. Check compression under the proposed attachment system.

XPS

Closed-cell extruded polystyrene can limit moisture uptake. Thickness, temperature and aging affect the documented thermal and vapor values. Keep foam surface-burning results separate from the wall assembly.

Polyiso

Faced polyisocyanurate can deliver high resistance in thinner sections. Foil and coated glass change vapor behavior, and aged board values vary with thickness. Coordinate facer and cladding with the wall detail.

Phenolic foam

A rigid thermoset core can provide high thermal resistance within a shallow cavity. Use the named product’s facer, evaluated thickness range and report. Exact-market moisture and mechanical evidence can be limited.

Regional and test-method limitations

Review the jurisdiction’s adopted IBC, IECC, ASHRAE 90.1, or applicable Canadian code and energy requirements. Check thermal and fire performance at the whole-wall level. ASTM C1303 and CAN/ULC-S770 LTTR, C1289-conditioned results, and ASTM C518 or C177 test readings are separate reporting bases. The reviewed sources do not establish comparable ASTM C1303 or Canadian CAN/ULC-S134 results. Environmental values have different scope and methodology and are presented without ranking.