Verified construction product

Johns Manville Corporation

AP Foil-Faced Polyiso Continuous Insulation

Polyiso board for above-grade exterior continuous insulation. Exterior wall sheathing.

Published technical facts

Specification record

Exterior wall assembly evidence
NFPA 285 listed designs · Intertek 29317 · U.S. · Check the individual JMC/FBI drawings for substrate, WRB, foam thickness, cladding, air cavity and openings. Confirm the current listing and project configuration. · Source
Wall applications and attachment
Exterior wall sheathing · Foil facers · stagger joints · Attachment and joint/penetration treatment depend on the assembly. The board is nonstructural. The sheet limits exposure to 60 days. · Source
Board sizes and availability
0.5–4.5 in · 4 × 8, 9 or 10 ft · Consult the thickness-specific U.S. table. Verify Canadian order sizes and thermal data for the project. · Source
Blowing agent
Hydrocarbon blend · Cyclopentane and isopentane · Portfolio material composition. Do not use this to infer the whole board’s environmental impact. · Source
Compressive resistance
≥16 psi · ASTM D1621 · The 2025 sheet does not state the endpoint strain. AP Foil25 is a distinct product. · Source
Environmental declaration and GWP
2.88 kg CO₂e · A1–A3 · TRACI 2.1 · 1 m² at RSI 1 · Production-weighted US/Canada polyiso sheathing family. A4, A5, C2 and C4 are reported separately. This is not an AP-only value. · Source
Noncombustibility
Combustible per manufacturer · Product warning · Coordinate any required thermal barrier. · Source
Surface burning
≤25 flame · ≤450 smoke · ASTM E84 · 4 in foam core · The same sheet describes the board as combustible. Fire behavior depends on the wall assembly. · Source
Thermal performance
R-6 at 1 in · R-26 at 4 in · ASTM C518 · C1289 aged values · Use the published board-only column. Exclude the reflective air space and do not extrapolate a constant per-inch value. · Source
Vapor permeance
0.05 US perms · ASTM E96 · foil-faced · 1 in minimum · The manufacturer describes a Class I vapor retarder at 1 in. The sheet does not state the E96 procedure. · Source
Water absorption or sorption
0.1 vol% · ASTM C1763 · procedure B · Water absorption and a wall’s water-resistive barrier role are separate properties. · Source

Comparison and technical evidence

← Explore related products