Verified construction product

Kingspan Insulation

Kooltherm K15 Rainscreen Board

Phenolic foam board for above-grade exterior continuous insulation. Rainscreen cladding.

Published technical facts

Specification record

Exterior wall assembly evidence
Exact K15 design unassessed · KIL/BI 30-02 specifies K122 · CCRR-1066 §6.4 calls for additional documentation for Types I–IV. Request an applicable K15 wall design and verify with the authority having jurisdiction. · Source
Wall applications and attachment
Rainscreen cladding · Foil-faced nonstructural board · The U.S. report requires a protected wall and disallows using the board as a siding nailing base. Fasteners must reach adequate backing. · Source
Board sizes and availability
25–100 mm evaluated range · Discrete stock sizes unverified · Confirm orderable dimensions and project-market availability with Kingspan. · Source
Board or core density
2.0 lb/ft³ nominal · Phenolic core · This is the listed nominal core density of K15, distinct from K100-series grades. · Source
Environmental declaration and GWP
European EPD located · Netherlands · 1 m² at 100 mm · The cited EPD models Tiel production and a distinct European declared configuration. Its numeric impact is excluded from the North American comparison. · Original URL unavailable

The manufacturer’s original download is unavailable. This historical Tiel declaration expired March 23, 2026. Distributor-hosted copy of the IBU declaration

Surface burning
≤25 flame · ≤450 smoke · UL 723 / ASTM E84 · foil-facing listing · The listed exterior wall fire design names K122. Do not transfer its result to K15. · Source
Thermal performance
R-6.8/in at 75°F · CCRR-1066 · 25–100 mm · Table 2 does not specify a thermal aging protocol or individual stock increments. No value derived outside the evaluated thickness range. · Source

Comparison and technical evidence

← Explore related products