Verified construction product

Henry

R2+ Matte Coated-Glass-Faced Polyiso

Polyiso board for above-grade exterior continuous insulation. Commercial above-grade exterior walls.

Published technical facts

Specification record

Exterior wall assembly evidence
NFPA 285 evaluation tables · DrJ TER 1407-01 · U.S. · Table 7 permits up to 4 in of Matte with claddings 1–6 and a 2 in maximum air gap, or 3.5 in with claddings 7–17, a 1.5 in maximum gap and the specified opening detail. Match the base wall, cavity insulation, sheathing, WRB and cladding restrictions, including tighter drainage-mat limits. For NFPA 285-12 use Table 13 and its own component options. Applicability is assembly-specific. Report subject to renewal October 1, 2027. · Source
Wall applications and attachment
Commercial above-grade exterior walls · Capped screws, adhesive or both · Check the wall detail and local approval. Cladding attachment transfers loads through the board to the supporting wall. · Source
Board sizes and availability
1–3.5 in tabulated · 16 or 24 in × 8 ft; 4 × 8 ft · Special-order 0.5–4.5 in range is documented. The thicker special-order range has no R-value table in the cited sheet. · Source
Compressive resistance
20 psi or 25 psi · ASTM D1621 · grades 2 or 3 · The base product has two distinct grades. Confirm the selected grade and the unreported test strain. · Source
Dimensional stability
2% linear change · ASTM D2126 · 7 days · Confirm conditioning details for any cross-product use. · Source
Surface burning
<75 flame · <450 smoke · ASTM E84 · foam core · Applies to the standard Matte sheet linked by Henry. Class A is a separate published designation. · Source
Thermal performance
R-6.0 at 1 in · R-21.7 at 3.5 in · ASTM C518 · 75°F · C1289 · CCW-3751 does not identify an aging duration or C1303 LTTR. No values assigned to unlisted special-order thicknesses. · Source
Vapor permeance
<1 US perm · ASTM E96 · 1 in coated-glass-faced board · The source does not identify the E96 procedure. Do not substitute the foil-faced product’s result. · Source
Water absorption or sorption
<0.1 vol% · ASTM C209 · The sheet limits ponding water exposure and prolonged direct sunlight exposure. · Source