Verified construction product

Owens Corning

FOAMULAR NGX 250

XPS board for above-grade exterior continuous insulation. Cavity walls and exterior CMU.

Published technical facts

Specification record

Exterior wall assembly evidence
NFPA 285 wall reference · Manufacturer wall example · U.S. · The CMU example names NGX 250 and notes performance for the specified component set. Obtain the exact tested construction and any permitted variations before relying on it. · Original URL unavailable

Owens Corning moved the CMU wall example. The current page names NGX 250 and conditions the fire reference on the selected components. Current manufacturer page for this wall example

Wall applications and attachment
Cavity walls and exterior CMU · Closed-cell Type IV XPS · Use the assembly’s fasteners and liquid flashing where specified. Verify support behind the board. · Original URL unavailable

Owens Corning moved the CMU wall example. The current page names NGX 250 and conditions the fire reference on the selected components. Current manufacturer page for this wall example

Board sizes and availability
¾–4 in · 24 or 48 in widths · 96 or 108 in lengths · Check thickness and edge combinations in the packaging table. Do not apply these U.S. rows to C-200 or C-300. · Source
Blowing agent
HFC-134a eliminated · NGX proprietary formulation · This is a blowing-agent disclosure, separate from the board’s lifecycle GWP. · Source
Compressive resistance
≥25 psi · ASTM D1621 · yield or 10% deflection · Whichever comes first. This grade property does not provide an allowable attachment or structural design load. · Source
Board or core density
≥1.55 lb/ft³ · ASTM D1622 · classification minimum · EPD Table 1 characterizes the U.S. grade. Actual product density may differ. · Source
Environmental declaration and GWP
7.08 kg CO₂e · A1–A3 · IPCC AR6 · 1 m² at RSI 1 · North American NGX family result including 250, with use and end-of-life modules reported separately. This is not a 250-only result. · Source
Dimensional stability
≤2% linear change · ASTM D2126 · Use the product data sheet test basis. · Source
Surface burning
10 flame · 175 smoke · ASTM E84 · UL U-197 reference · Confirm listed specimen thickness and certification conditions. · Source
Thermal performance
R-5.0 at 1 in · 75°F · ASTM C518 · 180-day real-time aging · At the same thickness the sheet lists R-5.4 at 40°F and R-5.6 at 25°F. CAN/ULC-S770-03 accelerated LTTR is a separate result of R-5.0 at 75°F. · Source
Vapor permeance
≤1.5 US perms · ASTM E96 · representative 1 in · unfaced · The procedure is unstated. Permeance decreases with thickness in the manufacturer’s notes. · Source
Water absorption or sorption
≤0.30 vol% · ASTM C272 · maximum · The laboratory endpoint differs from C1763, C209 and vapor sorption. · Source

Comparison and technical evidence

← Explore related products