Nexus Pavilion / Product Intelligence

Define the requirement.
Inspect the evidence.

Product Selection Intelligence for self-adhered air barriers. A focused workspace for documented wall applications, technical evidence and source-specific configurations.

Source-reviewed products
4
Manufacturer relationships
4
Active pilot cohort
Vapor permeable

Define the evidence you need

Your project brief

Published evidence, visible limitations
Building EnvelopeSelf-adhered sheetVapor permeable

This pilot covers 4 source-reviewed products. Define the project’s drying strategy before reviewing documented candidates.

Project application

Geography refers to the reviewed document’s stated scope. Availability, local compliance, substrate preparation and assembly compatibility require separate confirmation.

Selection intelligence / evidence brief

Your product evidence shortlist

4 documented matches0 need evidence0 outside this brief

Matches satisfy the selected documentation criteria. They establish a basis for technical review. Suitability and compliance remain unassessed. Products retain the published cohort order, with unresolved evidence shown separately.

0 / 3 selected for comparison

Select two or three products using the overview or card controls.

Open existing cohort matrix ↗

Product Evidence Overview

All 4 eligible cohort records. Brief status reflects documentation criteria. Numerical results and thresholds remain distinct evidence forms.

Compare evidence at a glance Scroll to review all columns →
Product / brief statusMaterial resultNominal thicknessSource statusSelect
SOPRASEAL STICK VPDocumented matchNumerical result0.0025 L/(s·m²) @ 75 Pa0.6 mm (24 mils)Reviewed manufacturer documentTDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market only
DELTA-VENT SADocumented matchQualified threshold< 0.02 L/(s·m²) @ 75 PaMissing evidenceReviewed manufacturer documentTechnical Data Sheet dated 2025-04-15; North American document
PERM-A-BARRIER VPS 30Documented matchQualified threshold< 0.02 L/(s·m²) @ 75 PaMissing evidenceReviewed manufacturer documentOnline data sheet last updated 2026-06-23; valid for United States use only
WrapShield SADocumented matchNumerical result0.0001 L/(s·m²) @ 75 Pa0.5743 mm (22.61 mil)Source-access limitation
Current revision unconfirmed
Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17
Documented match
SOPREMA

SOPRASEAL STICK VP

  • Published full-wall, self-adhered sheet application · Manufacturer-stated vapor-permeable classification
Material air permeance (ASTM E2178)
0.0025 L/(s·m²) @ 75 PaSource-checked manufacturer specification · Numerical result
Water-vapor permeance (ASTM E96/E96M)
629 ng/(Pa·s·m²) (11 perm) Procedure A; 802 ng/(Pa·s·m²) (14 perm) Procedure B
Nominal thickness
0.6 mm (24 mils)
Application, configuration & source limits
Material composition
Tri-laminated polypropylene facer with self-adhesive underface covered by silicone release film (manufacturer TDS)
Substrate compatibility
Most substrates such as masonry, concrete, wood, and gypsum (manufacturer recommended substrates)
Installation temperature limits
-7°C to 40°C (19°F to 104°F)

Document edition
TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market only

All TDS values are nominal. E96 temperature/RH not stated. Primer may be needed for jobsite conditions; follow current detailing instructions.

Material claim only. Do not treat this row as ASTM E2357 / CAN/ULC-S742 assembly leakage or as local code compliance.

Documented match
Dörken Systems

DELTA-VENT SA

  • Published full-wall, self-adhered sheet application · Manufacturer-stated vapor-permeable classification
Material air permeance (ASTM E2178)
Qualified threshold: Pass (< 0.02 L/(s·m²) @ 75 Pa). This is not an exact measured permeance value; a more precise ASTM E2178 result was not stated on the reviewed TDSSource-checked manufacturer specification · Qualified threshold
Water-vapor permeance (ASTM E96/E96M)
35 US perms (ASTM E96-05 Procedure A); 50 US perms (Procedure B). Temperature/RH not stated; inconsistent bracketed grain-unit figures excluded
Nominal thickness
Not disclosed in reviewed manufacturer sources
Application, configuration & source limits
Material composition
Three-layer membrane: high-strength spunbonded polypropylene outer layers thermally bonded to a vapor-permeable watertight TPU middle layer, with full-surface pressure-sensitive adhesive (manufacturer TDS)
Substrate compatibility
Concrete, masonry, OSB, plywood, or exterior grade drywall; primer products listed where required (DELTA-HF PRIMER / DELTA-ADHESIVE family)
Installation temperature limits
Minimum 40°F (5°C)

Document edition
Technical Data Sheet dated 2025-04-15; North American document

ASTM E96-05 Procedures A/B; temperature/RH not stated. Inconsistent bracketed grain-unit figures are excluded; retain the stated perm values. Confirm primer and accessory compatibility.

Qualified ASTM E2178 threshold/pass only — not an exact measured permeance. Do not treat as numerically equivalent to precise E2178 values, and do not substitute assembly ASTM E2357 / CAN/ULC-S742 leakage or local code compliance.

Documented match
GCP Applied Technologies

PERM-A-BARRIER VPS 30

  • Published full-wall, self-adhered sheet application · Manufacturer-stated vapor-permeable classification
Material air permeance (ASTM E2178)
Qualified threshold: < 0.02 L/(s·m²) @ 75 Pa (0.004 cfm/ft² nominal equivalent). This is a reported upper bound, not an exact measured permeance; the reviewed sheet does not label this result PassSource-checked manufacturer specification · Qualified threshold
Water-vapor permeance (ASTM E96/E96M)
13.9 perms (ASTM E96 Method B, wet cup). Method A / dry-cup permeance was not stated on the reviewed data sheet
Nominal thickness
Not disclosed in reviewed manufacturer sources
Application, configuration & source limits
Material composition
Proprietary breathable carrier film with specially designed adhesive; primerless self-adhered vapor-permeable sheet (manufacturer data sheet)
Substrate compatibility
Prepared wall substrates including gypsum (manufacturer notes priming gypsum cut edges to reduce dust) and OSB with PERM-A-BARRIER Adhesive Primer recommended before membrane application (manufacturer data sheet)
Installation temperature limits
Air and surface temperatures above 0°F (-17.78°C)

Document edition
Online data sheet last updated 2026-06-23; valid for United States use only

E96 Method B only; temperature/RH and Method A not stated. Installation section requires air and surface temperatures above 0°F; the overview says at or above. Confirm the boundary with GCP. OSB primer recommended.

Qualified ASTM E2178 threshold/pass only — not an exact measured permeance. Do not treat as numerically equivalent to precise E2178 values, and do not substitute assembly ASTM E2357 / CAN/ULC-S742 leakage or local code compliance.

Documented match
VaproShield

WrapShield SA

  • Published full-wall, self-adhered sheet application · Manufacturer-stated vapor-permeable classification

Source-access limitation · Current document revision requires confirmation. See source qualifications.

Material air permeance (ASTM E2178)
0.0001 L/(s·m²) @ 75 Pa (manufacturer-reported result). Rounded imperial zero omitted; it does not mean zero leakageManufacturer claim · Numerical result
Water-vapor permeance (ASTM E96/E96M)
40.45 US perms (Procedure A / desiccant, 2314 ng/(Pa·s·m²)); 50.45 US perms (Procedure B / water, 2886 ng/(Pa·s·m²)); both at 24.4°C and 50% RH
Nominal thickness
0.5743 mm (22.61 mil)
Application, configuration & source limits
Material composition
Self-adhered vapor-permeable water-resistive / air-barrier sheet; orange top face and white back per manufacturer physical-properties table
Substrate compatibility
Peel-adhesion substrates documented on the product page include DensGlass Gold, plywood, concrete, and CMU (no peeling, buckling, or ripping in the reviewed adhesion table)
Installation temperature limits
Minimum 20°F and rising; PDS table gives -6.6°C, installation text rounds to -6°C

Document edition
Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17

Direct retrieval returned HTTP 403; official indexed PDF reviewed, current revision not independently confirmed. E96 A/B: 24.4°C, 50% RH. E2357 imperial limits differ between PDF and web table and are not equivalent to the SI limit; only the shared SI value is retained. Confirm current data with VaproShield. A ventilated vertical drainage cavity is required.

Material claim only. Do not treat this row as ASTM E2357 / CAN/ULC-S742 assembly leakage or as local code compliance.

Commercial Roofing Intelligence →
Below-Grade Waterproofing Intelligence →
Exterior Continuous Insulation Intelligence →
Architectural Expansion Joint Intelligence →