| Joint opening4 in nominal models and their documented family ranges. | 4 in nominal SSR 200–400 family · 2–4 in Source ↗Details4 in nominal The floor-to-floor SSR models are offered at 2, 3 and 4 in nominal. The SSR-400 is the 4 in configuration. DS.SSRSSRW200-400.0323 · SSR model table | 4 in nominal Rev. 11 A01 table · 2–12 in Source ↗Details4 in nominal The movement chart tabulates 2 through 12 in A01 models. The product page advertises larger family sizes. Confirm configuration and shop drawings for sizes beyond the chart. IPC.855 Rev. 11 · Movement Charts, A01 | 4 in nominal A01 family · 2–8 in Source ↗Details4 in nominal The floor-to-floor chart lists 2, 4, 6 and 8 in A01 models. IPC.1581 Rev. 4 · A01 movement table | 4 in nominal PJC family · 2–24 in Source ↗Details4 in nominal The drawing labels a 4 in joint. The series page lists a 2–24 in family. Confirm operating limits and tolerances against the project-specific schedule. July 11, 2024 · Joint dimension | 4 in nominal SPJ family · 2–18 in Source ↗Details4 in nominal Select SPJ-400 in the standard movement table. The compact SPJ-400C is a separate model with a different movement value. See product data sheet · Movement Table |
|---|
| Seismic movementManufacturer-reported limits and axes for each configuration. | 1.50–8.50 in opening Asymmetric opening limits Source ↗Details1.50–8.50 in opening At 4 in nominal, the opening limits imply 2.50 in of closure and 4.50 in of opening. The sheet describes lateral movement without a numerical lateral or vertical limit. DS.SSRSSRW200-400.0323 · SSR-400 row and Technical Data | ±2 in horizontal and vertical A01 4 in movement chart Source ↗Details±2 in horizontal and vertical The chart shows ±2 in on both listed axes for 501-A01-100. Higher horizontal movement is a modification. Confirm shear, combined-axis behavior and limits. IPC.855 Rev. 11 · A01 movement chart and Modifiable Options | ±2 in horizontal and vertical A01 4 in movement chart Source ↗Details±2 in horizontal and vertical The guide describes unrestricted lateral movement. Confirm lateral limits at terminations and transitions and simultaneous-axis performance. IPC.1581 Rev. 4 · Product Guide and A01 movement table | 50% movement Model drawing · manufacturer notation Source ↗Details50% movement The PJC-2-4 drawing labels movement at 50%. The series page cites ASTM E1399 and gives separate axial and lateral ranges. Confirm model-specific directional values, vertical shear and operating endpoints. July 11, 2024 · Movement callout | 4.75 in total travel SPJ-400 · total as reported Source ↗Details4.75 in total travel The table reports total movement without giving opening and closing endpoints. The product family supports lateral shear and vertical displacement. Confirm model-specific directional limits. See product data sheet · Description and Movement Table |
|---|
| Traffic and loadKeep wheel, concentrated and distributed load evidence distinct. | 500 lb standard loading Load basis unstated in sheet Source ↗Details500 lb standard loading The sheet gives a 500 lb figure. Request the contact area, wheel or pedestrian load class and test or design basis for this model. DS.SSRSSRW200-400.0323 · Standard Loading | Moderate · rolling option Stainless seal caps for rolling loads Source ↗DetailsModerate · rolling option Inpro's guide specification classifies the standard pan system as moderate loading. The technical data show a modified 4 in system with gussets and stainless seal caps. Confirm wheel load and contact footprint. IPC.855 Rev. 11 · Modifiable Options, 501-A01-100 cutaway | Moderate standard loading Heavy capability also advertised Source ↗DetailsModerate standard loading The product page lists Moderate under Loading Class and Heavy Load in its description. The guide specification calls standard loading moderate, with heavy concentrated loads requiring a modified profile. Request wheel and contact-area evidence. Page revision unstated · Loading Class and Description | Pedestrian, gurney and X-ray Documented load categories Source ↗DetailsPedestrian, gurney and X-ray The technical sheet lists pedestrian, gurney/bed and X-ray categories. Confirm the point load and contact area for equipment and joint width. Rev. 03/21 · Performance, Loading | 150 psf distributed live load Foot and rolling traffic described Source ↗Details150 psf distributed live load Sika Emseal describes pedestrian and rolling traffic on the flush cover. The numerical load is distributed across the pan. Ask for contact-area and concentrated wheel-load evidence. See product data sheet · Description |
|---|
| InstallationRecessed floor-to-floor pan and blockout configuration. | Recessed turnbar pan Floor-to-floor · 2 in blockout height Source ↗DetailsRecessed turnbar pan The aluminum center pan is supported by frames and positioned by a turnbar. The data sheet lists a 6.25 in blockout width for this model. DS.SSRSSRW200-400.0323 · SSR section and SSR-400 row | Recessed pop-up pan Floor-to-floor · centerbar and post Source ↗DetailsRecessed pop-up pan Rev. 11 shows a 2 1/8 in frame height and 4 3/4 in blockout dimension for the selected A01 row. Use the matching drawing for the supplied configuration. IPC.855 Rev. 11 · A01 movement chart and Pop-Up Seismic Floor Systems | Recessed hinged pan Floor-to-floor · asymmetric framing Source ↗DetailsRecessed hinged pan The hinged pan rides up the canted frame under seismic movement. At 4 in nominal, the chart gives a 2 in H1 frame height, 5 1/2 in H2 and 7 3/8 in blockout dimension. IPC.1581 Rev. 4 · A01 movement chart and hinged pan section | Recessed centering-bar pan Floor-to-floor · blockout only Source ↗DetailsRecessed centering-bar pan Two aluminum frames support the infill pan. The PJC uses a centering device. The PJCL floor-to-wall variant is outside the comparison. Page revision unstated · Features and Floor-to-Floor details | Recessed centering-bar pan Deck-to-deck · concrete blockouts Source ↗DetailsRecessed centering-bar pan Recessed edge frames and a seismic centering bar support the pan. Review the deck-to-deck detail for SPJ-400 and coordinate field infill and sealant. Rev. A · May 1, 2024 · SPJ 400–1800 deck-to-deck condition |
|---|
| Floor finishPan depth and documented infill compatibility. | Up to 1 in infill Deep aluminum center pan Source ↗DetailsUp to 1 in infill The manufacturer documents a recess for thicker floor finishes. Verify the finish buildup and weight with the manufacturer. Page revision unstated · Product overview | 1 7/8 in deep pan Stone, pavers and tile interface Source ↗Details1 7/8 in deep pan Inpro lists marble, granite, limestone and pavers. The pan edge permits a 3/8 in tile to abut without beveling. IPC.855 Rev. 11 · Product Guide | 1 5/8 in deep pan Stone, pavers and tile interface Source ↗Details1 5/8 in deep pan Inpro lists marble, granite, limestone and pavers. The edge detail accommodates abutting tile up to 3/8 in. IPC.1581 Rev. 4 · Product Guide | Deep finish infill Pan filled to match adjacent flooring Source ↗DetailsDeep finish infill Balco identifies deep floor finishes as the intended use. Confirm the selected pan depth, finish buildup and infill weight. Rev. 03/21 · Product Description and Advantages | Tile, stone, terrazzo and more Finish infill at the walking surface Source ↗DetailsTile, stone, terrazzo and more The publisher also lists carpet, hardwood, vinyl and concrete. Confirm finish build-up for the selected detail. Page revision unstated · Product overview and Features |
|---|
| Fire documentationBarrier options, rated details and complete assembly evidence. | 2-hour barrier shown Manufacturer detail · listing match open Source ↗Details2-hour barrier shown The SSR-400 drawing shows a barrier labeled 2-hour. Obtain the applicable tested floor-joint design and verify cover, slab, opening and movement against it. May 1, 2023 · SSR-400 W/ FB section | Optional fire barrier Cover detail · listing match open Source ↗DetailsOptional fire barrier The 501 drawing shows a barrier. Fireline 520 literature provides separate blanket test and movement information. Confirm the listed floor design and approved integration for the selected cover. IPC.855 Rev. 11 · Options, Fire Barrier System | Optional fire blanket Cover detail · listing match open Source ↗DetailsOptional fire blanket Rev. 4 illustrates a blanket beneath the 4 in floor cover. Fireline 520 literature provides separate blanket test and movement information. Verify the exact listed design and integration before taking credit. IPC.1581 Rev. 4 · Options, Fire Barrier System | 2-hour floor-joint listing referenced 2HPJC-2-4-MBF · UL FF-D-1138 Source ↗Details2-hour floor-joint listing referenced The 2HPJC detail identifies MetaBlock MBF2H0600 and calls for a 9 1/2 in minimum slab. UL FF-D-1138 describes the 2-hour assembly at 4 in nominal, class II and III movement of 50% compression or extension, a 6 in maximum extended opening and a generic metal cover with retaining strap. Confirm current listing scope and the exact PJC pan detail against those requirements. October 28, 2022 · Barrier, UL listing and minimum slab callouts | Emshield DFR option UL 2079 barrier documentation · assembly open Source ↗DetailsEmshield DFR option The SPJ page identifies DFR as an add-on and directs users to confirm sizes. DFR2 literature describes the barrier's tested conditions. Verify the listed geometry and movement envelope with the SPJ cover in place. Page revision unstated · Product overview, Emshield DFR option |
|---|