Compare five recessed, infillable seismic pans for 4 in nominal openings in interior floors.

Floor-to-floor · U.S. product documentation

Quick decision

Choose one evidence screen

Relevant evidence

5 of 5 variants

Find published seismic movement evidence for the compared pans.

  • Construction Specialties · SSR-400

    Why it surfaced
    1.50–8.50 in opening · At 4 in nominal, the opening limits imply 2.50 in of closure and 4.50 in of opening. The sheet describes lateral movement without a numerical lateral or vertical limit.
  • Inpro · 501 Series A01

    Why it surfaced
    ±2 in horizontal and vertical · The chart shows ±2 in on both listed axes for 501-A01-100. Higher horizontal movement is a modification. Confirm shear, combined-axis behavior and limits.
  • Inpro · 502 Hinged Pan A01

    Why it surfaced
    ±2 in horizontal and vertical · The guide describes unrestricted lateral movement. Confirm lateral limits at terminations and transitions and simultaneous-axis performance.
  • Balco · PJC ConVerge

    Why it surfaced
    50% movement · The PJC-2-4 drawing labels movement at 50%. The series page cites ASTM E1399 and gives separate axial and lateral ranges. Confirm model-specific directional values, vertical shear and operating endpoints.
  • Sika Emseal · Wabo SeismicPan SPJ

    Why it surfaced
    4.75 in total travel · The table reports total movement without giving opening and closing endpoints. The product family supports lateral shear and vertical displacement. Confirm model-specific directional limits.

Seismic movement. 5 variants with relevant documentation. 0 unassessed.

Information & Decision Support Notice

Global Construction Network (GCN), operated by Nexus Pavilion Inc., provides informational research, product comparisons and decision support based on published manufacturer documentation and identified third-party sources.

Technical specifications and performance values attributed to manufacturers are manufacturer-reported. GCN does not independently test or certify products, guarantee their performance, or warrant the accuracy, completeness or currency of third-party information.

Search results, comparisons and screening outputs are intended to support preliminary research and do not constitute engineering advice, professional certification, regulatory approval or confirmation of project-specific suitability.

Users must independently verify current specifications, product configurations, manufacturer requirements and applicable regulations before making specification, purchasing or installation decisions.

Third-party intellectual property remains subject to its respective owners' rights. References to manufacturers and products do not imply endorsement, sponsorship or affiliation.

Use of GCN is subject to the applicable Nexus Pavilion Inc. Terms of Use.

Product comparison

Values retain their reported basis. Different test methods or conditions limit direct comparison.

Scroll across to compare all 5 joint covers.

Key expansion joint cover differences — Architectural Expansion Joint Intelligence
CriterionRecessed seismic floor pans
SSR-400Construction Specialties501 Series A01Inpro502 Hinged Pan A01InproPJC ConVergeBalcoWabo SeismicPan SPJSika Emseal
Joint opening4 in nominal models and their documented family ranges.

4 in nominal

SSR 200–400 family · 2–4 in

Source
Details

4 in nominal

The floor-to-floor SSR models are offered at 2, 3 and 4 in nominal. The SSR-400 is the 4 in configuration.

DS.SSRSSRW200-400.0323 · SSR model table

4 in nominal

Rev. 11 A01 table · 2–12 in

Source
Details

4 in nominal

The movement chart tabulates 2 through 12 in A01 models. The product page advertises larger family sizes. Confirm configuration and shop drawings for sizes beyond the chart.

IPC.855 Rev. 11 · Movement Charts, A01

4 in nominal

A01 family · 2–8 in

Source
Details

4 in nominal

The floor-to-floor chart lists 2, 4, 6 and 8 in A01 models.

IPC.1581 Rev. 4 · A01 movement table

4 in nominal

PJC family · 2–24 in

Source
Details

4 in nominal

The drawing labels a 4 in joint. The series page lists a 2–24 in family. Confirm operating limits and tolerances against the project-specific schedule.

July 11, 2024 · Joint dimension

4 in nominal

SPJ family · 2–18 in

Source
Details

4 in nominal

Select SPJ-400 in the standard movement table. The compact SPJ-400C is a separate model with a different movement value.

See product data sheet · Movement Table

Seismic movementManufacturer-reported limits and axes for each configuration.

1.50–8.50 in opening

Asymmetric opening limits

Source
Details

1.50–8.50 in opening

At 4 in nominal, the opening limits imply 2.50 in of closure and 4.50 in of opening. The sheet describes lateral movement without a numerical lateral or vertical limit.

DS.SSRSSRW200-400.0323 · SSR-400 row and Technical Data

±2 in horizontal and vertical

A01 4 in movement chart

Source
Details

±2 in horizontal and vertical

The chart shows ±2 in on both listed axes for 501-A01-100. Higher horizontal movement is a modification. Confirm shear, combined-axis behavior and limits.

IPC.855 Rev. 11 · A01 movement chart and Modifiable Options

±2 in horizontal and vertical

A01 4 in movement chart

Source
Details

±2 in horizontal and vertical

The guide describes unrestricted lateral movement. Confirm lateral limits at terminations and transitions and simultaneous-axis performance.

IPC.1581 Rev. 4 · Product Guide and A01 movement table

50% movement

Model drawing · manufacturer notation

Source
Details

50% movement

The PJC-2-4 drawing labels movement at 50%. The series page cites ASTM E1399 and gives separate axial and lateral ranges. Confirm model-specific directional values, vertical shear and operating endpoints.

July 11, 2024 · Movement callout

4.75 in total travel

SPJ-400 · total as reported

Source
Details

4.75 in total travel

The table reports total movement without giving opening and closing endpoints. The product family supports lateral shear and vertical displacement. Confirm model-specific directional limits.

See product data sheet · Description and Movement Table

Traffic and loadKeep wheel, concentrated and distributed load evidence distinct.

500 lb standard loading

Load basis unstated in sheet

Source
Details

500 lb standard loading

The sheet gives a 500 lb figure. Request the contact area, wheel or pedestrian load class and test or design basis for this model.

DS.SSRSSRW200-400.0323 · Standard Loading

Moderate · rolling option

Stainless seal caps for rolling loads

Source
Details

Moderate · rolling option

Inpro's guide specification classifies the standard pan system as moderate loading. The technical data show a modified 4 in system with gussets and stainless seal caps. Confirm wheel load and contact footprint.

IPC.855 Rev. 11 · Modifiable Options, 501-A01-100 cutaway

Moderate standard loading

Heavy capability also advertised

Source
Details

Moderate standard loading

The product page lists Moderate under Loading Class and Heavy Load in its description. The guide specification calls standard loading moderate, with heavy concentrated loads requiring a modified profile. Request wheel and contact-area evidence.

Page revision unstated · Loading Class and Description

Pedestrian, gurney and X-ray

Documented load categories

Source
Details

Pedestrian, gurney and X-ray

The technical sheet lists pedestrian, gurney/bed and X-ray categories. Confirm the point load and contact area for equipment and joint width.

Rev. 03/21 · Performance, Loading

150 psf distributed live load

Foot and rolling traffic described

Source
Details

150 psf distributed live load

Sika Emseal describes pedestrian and rolling traffic on the flush cover. The numerical load is distributed across the pan. Ask for contact-area and concentrated wheel-load evidence.

See product data sheet · Description

InstallationRecessed floor-to-floor pan and blockout configuration.

Recessed turnbar pan

Floor-to-floor · 2 in blockout height

Source
Details

Recessed turnbar pan

The aluminum center pan is supported by frames and positioned by a turnbar. The data sheet lists a 6.25 in blockout width for this model.

DS.SSRSSRW200-400.0323 · SSR section and SSR-400 row

Recessed pop-up pan

Floor-to-floor · centerbar and post

Source
Details

Recessed pop-up pan

Rev. 11 shows a 2 1/8 in frame height and 4 3/4 in blockout dimension for the selected A01 row. Use the matching drawing for the supplied configuration.

IPC.855 Rev. 11 · A01 movement chart and Pop-Up Seismic Floor Systems

Recessed hinged pan

Floor-to-floor · asymmetric framing

Source
Details

Recessed hinged pan

The hinged pan rides up the canted frame under seismic movement. At 4 in nominal, the chart gives a 2 in H1 frame height, 5 1/2 in H2 and 7 3/8 in blockout dimension.

IPC.1581 Rev. 4 · A01 movement chart and hinged pan section

Recessed centering-bar pan

Floor-to-floor · blockout only

Source
Details

Recessed centering-bar pan

Two aluminum frames support the infill pan. The PJC uses a centering device. The PJCL floor-to-wall variant is outside the comparison.

Page revision unstated · Features and Floor-to-Floor details

Recessed centering-bar pan

Deck-to-deck · concrete blockouts

Source
Details

Recessed centering-bar pan

Recessed edge frames and a seismic centering bar support the pan. Review the deck-to-deck detail for SPJ-400 and coordinate field infill and sealant.

Rev. A · May 1, 2024 · SPJ 400–1800 deck-to-deck condition

Floor finishPan depth and documented infill compatibility.

Up to 1 in infill

Deep aluminum center pan

Source
Details

Up to 1 in infill

The manufacturer documents a recess for thicker floor finishes. Verify the finish buildup and weight with the manufacturer.

Page revision unstated · Product overview

1 7/8 in deep pan

Stone, pavers and tile interface

Source
Details

1 7/8 in deep pan

Inpro lists marble, granite, limestone and pavers. The pan edge permits a 3/8 in tile to abut without beveling.

IPC.855 Rev. 11 · Product Guide

1 5/8 in deep pan

Stone, pavers and tile interface

Source
Details

1 5/8 in deep pan

Inpro lists marble, granite, limestone and pavers. The edge detail accommodates abutting tile up to 3/8 in.

IPC.1581 Rev. 4 · Product Guide

Deep finish infill

Pan filled to match adjacent flooring

Source
Details

Deep finish infill

Balco identifies deep floor finishes as the intended use. Confirm the selected pan depth, finish buildup and infill weight.

Rev. 03/21 · Product Description and Advantages

Tile, stone, terrazzo and more

Finish infill at the walking surface

Source
Details

Tile, stone, terrazzo and more

The publisher also lists carpet, hardwood, vinyl and concrete. Confirm finish build-up for the selected detail.

Page revision unstated · Product overview and Features

Fire documentationBarrier options, rated details and complete assembly evidence.

2-hour barrier shown

Manufacturer detail · listing match open

Source
Details

2-hour barrier shown

The SSR-400 drawing shows a barrier labeled 2-hour. Obtain the applicable tested floor-joint design and verify cover, slab, opening and movement against it.

May 1, 2023 · SSR-400 W/ FB section

Optional fire barrier

Cover detail · listing match open

Source
Details

Optional fire barrier

The 501 drawing shows a barrier. Fireline 520 literature provides separate blanket test and movement information. Confirm the listed floor design and approved integration for the selected cover.

IPC.855 Rev. 11 · Options, Fire Barrier System

Optional fire blanket

Cover detail · listing match open

Source
Details

Optional fire blanket

Rev. 4 illustrates a blanket beneath the 4 in floor cover. Fireline 520 literature provides separate blanket test and movement information. Verify the exact listed design and integration before taking credit.

IPC.1581 Rev. 4 · Options, Fire Barrier System

2-hour floor-joint listing referenced

2HPJC-2-4-MBF · UL FF-D-1138

Source
Details

2-hour floor-joint listing referenced

The 2HPJC detail identifies MetaBlock MBF2H0600 and calls for a 9 1/2 in minimum slab. UL FF-D-1138 describes the 2-hour assembly at 4 in nominal, class II and III movement of 50% compression or extension, a 6 in maximum extended opening and a generic metal cover with retaining strap. Confirm current listing scope and the exact PJC pan detail against those requirements.

October 28, 2022 · Barrier, UL listing and minimum slab callouts

Emshield DFR option

UL 2079 barrier documentation · assembly open

Source
Details

Emshield DFR option

The SPJ page identifies DFR as an add-on and directs users to confirm sizes. DFR2 literature describes the barrier's tested conditions. Verify the listed geometry and movement envelope with the SPJ cover in place.

Page revision unstated · Product overview, Emshield DFR option

Technical evidence

Manufacturer documents checked November 27, 2026. Each model has six source-linked evidence fields.

SSR-400

Construction Specialties · SSR-400 · Official product page

Technical evidence for SSR-400 (6)
Joint opening
4 in nominal · SSR 200–400 family · 2–4 in

The floor-to-floor SSR models are offered at 2, 3 and 4 in nominal. The SSR-400 is the 4 in configuration.

SSR and SSRW 200–400 technical data · DS.SSRSSRW200-400.0323 · SSR model table

Seismic movement
1.50–8.50 in opening · Asymmetric opening limits

At 4 in nominal, the opening limits imply 2.50 in of closure and 4.50 in of opening. The sheet describes lateral movement without a numerical lateral or vertical limit.

SSR and SSRW 200–400 technical data · DS.SSRSSRW200-400.0323 · SSR-400 row and Technical Data

Traffic and load
500 lb standard loading · Load basis unstated in sheet

The sheet gives a 500 lb figure. Request the contact area, wheel or pedestrian load class and test or design basis for this model.

SSR and SSRW 200–400 technical data · DS.SSRSSRW200-400.0323 · Standard Loading

Installation
Recessed turnbar pan · Floor-to-floor · 2 in blockout height

The aluminum center pan is supported by frames and positioned by a turnbar. The data sheet lists a 6.25 in blockout width for this model.

SSR and SSRW 200–400 technical data · DS.SSRSSRW200-400.0323 · SSR section and SSR-400 row

Floor finish
Up to 1 in infill · Deep aluminum center pan

The manufacturer documents a recess for thicker floor finishes. Verify the finish buildup and weight with the manufacturer.

SSR 2–4 in product page · Page revision unstated · Product overview

Fire documentation
2-hour barrier shown · Manufacturer detail · listing match open

The SSR-400 drawing shows a barrier labeled 2-hour. Obtain the applicable tested floor-joint design and verify cover, slab, opening and movement against it.

SSR-400 with fire barrier drawing · May 1, 2023 · SSR-400 W/ FB section

501 Series A01

Inpro · J501-A01-100 · Official product page

Technical evidence for 501 Series A01 (6)
Joint opening
4 in nominal · Rev. 11 A01 table · 2–12 in

The movement chart tabulates 2 through 12 in A01 models. The product page advertises larger family sizes. Confirm configuration and shop drawings for sizes beyond the chart.

501 Series A01/A02 technical data · IPC.855 Rev. 11 · Movement Charts, A01

501 Series Pan System product page · Page revision unstated · Description and modifiable options

Seismic movement
±2 in horizontal and vertical · A01 4 in movement chart

The chart shows ±2 in on both listed axes for 501-A01-100. Higher horizontal movement is a modification. Confirm shear, combined-axis behavior and limits.

501 Series A01/A02 technical data · IPC.855 Rev. 11 · A01 movement chart and Modifiable Options

Traffic and load
Moderate · rolling option · Stainless seal caps for rolling loads

Inpro's guide specification classifies the standard pan system as moderate loading. The technical data show a modified 4 in system with gussets and stainless seal caps. Confirm wheel load and contact footprint.

501 Series A01/A02 technical data · IPC.855 Rev. 11 · Modifiable Options, 501-A01-100 cutaway

JointMaster guide specification · IPC.3087 Rev. 5 · Part 2, Narrow Sightline / Pan Coverplate Systems

Installation
Recessed pop-up pan · Floor-to-floor · centerbar and post

Rev. 11 shows a 2 1/8 in frame height and 4 3/4 in blockout dimension for the selected A01 row. Use the matching drawing for the supplied configuration.

501 Series A01/A02 technical data · IPC.855 Rev. 11 · A01 movement chart and Pop-Up Seismic Floor Systems

Floor finish
1 7/8 in deep pan · Stone, pavers and tile interface

Inpro lists marble, granite, limestone and pavers. The pan edge permits a 3/8 in tile to abut without beveling.

501 Series A01/A02 technical data · IPC.855 Rev. 11 · Product Guide

Fire documentation
Optional fire barrier · Cover detail · listing match open

The 501 drawing shows a barrier. Fireline 520 literature provides separate blanket test and movement information. Confirm the listed floor design and approved integration for the selected cover.

501 Series A01/A02 technical data · IPC.855 Rev. 11 · Options, Fire Barrier System

Fireline 520 blanket technical data · IPC.1831 Rev. 8 · Product Guide

502 Hinged Pan A01

Inpro · J502-A01-100 · Official product page

Technical evidence for 502 Hinged Pan A01 (6)
Joint opening
4 in nominal · A01 family · 2–8 in

The floor-to-floor chart lists 2, 4, 6 and 8 in A01 models.

502 Series A01/A02 technical data · IPC.1581 Rev. 4 · A01 movement table

Seismic movement
±2 in horizontal and vertical · A01 4 in movement chart

The guide describes unrestricted lateral movement. Confirm lateral limits at terminations and transitions and simultaneous-axis performance.

502 Series A01/A02 technical data · IPC.1581 Rev. 4 · Product Guide and A01 movement table

Traffic and load
Moderate standard loading · Heavy capability also advertised

The product page lists Moderate under Loading Class and Heavy Load in its description. The guide specification calls standard loading moderate, with heavy concentrated loads requiring a modified profile. Request wheel and contact-area evidence.

502 Series J502-A01-100 product page · Page revision unstated · Loading Class and Description

JointMaster guide specification · IPC.3087 Rev. 5 · Part 2, Narrow Sightline / Pan Coverplate Systems

Installation
Recessed hinged pan · Floor-to-floor · asymmetric framing

The hinged pan rides up the canted frame under seismic movement. At 4 in nominal, the chart gives a 2 in H1 frame height, 5 1/2 in H2 and 7 3/8 in blockout dimension.

502 Series A01/A02 technical data · IPC.1581 Rev. 4 · A01 movement chart and hinged pan section

Floor finish
1 5/8 in deep pan · Stone, pavers and tile interface

Inpro lists marble, granite, limestone and pavers. The edge detail accommodates abutting tile up to 3/8 in.

502 Series A01/A02 technical data · IPC.1581 Rev. 4 · Product Guide

Fire documentation
Optional fire blanket · Cover detail · listing match open

Rev. 4 illustrates a blanket beneath the 4 in floor cover. Fireline 520 literature provides separate blanket test and movement information. Verify the exact listed design and integration before taking credit.

502 Series A01/A02 technical data · IPC.1581 Rev. 4 · Options, Fire Barrier System

Fireline 520 blanket technical data · IPC.1831 Rev. 8 · Product Guide

PJC ConVerge

Balco · PJC-2-4 · Official product page

Technical evidence for PJC ConVerge (6)
Joint opening
4 in nominal · PJC family · 2–24 in

The drawing labels a 4 in joint. The series page lists a 2–24 in family. Confirm operating limits and tolerances against the project-specific schedule.

PJC-2-4 floor-to-floor drawing · July 11, 2024 · Joint dimension

PJC ConVerge product page · Page revision unstated · Joint Size

Seismic movement
50% movement · Model drawing · manufacturer notation

The PJC-2-4 drawing labels movement at 50%. The series page cites ASTM E1399 and gives separate axial and lateral ranges. Confirm model-specific directional values, vertical shear and operating endpoints.

PJC-2-4 floor-to-floor drawing · July 11, 2024 · Movement callout

PJC ConVerge product page · Page revision unstated · Movement and Performance

Traffic and load
Pedestrian, gurney and X-ray · Documented load categories

The technical sheet lists pedestrian, gurney/bed and X-ray categories. Confirm the point load and contact area for equipment and joint width.

PJC and PJCL technical data · Rev. 03/21 · Performance, Loading

Installation
Recessed centering-bar pan · Floor-to-floor · blockout only

Two aluminum frames support the infill pan. The PJC uses a centering device. The PJCL floor-to-wall variant is outside the comparison.

PJC ConVerge product page · Page revision unstated · Features and Floor-to-Floor details

Floor finish
Deep finish infill · Pan filled to match adjacent flooring

Balco identifies deep floor finishes as the intended use. Confirm the selected pan depth, finish buildup and infill weight.

PJC and PJCL technical data · Rev. 03/21 · Product Description and Advantages

Fire documentation
2-hour floor-joint listing referenced · 2HPJC-2-4-MBF · UL FF-D-1138

The 2HPJC detail identifies MetaBlock MBF2H0600 and calls for a 9 1/2 in minimum slab. UL FF-D-1138 describes the 2-hour assembly at 4 in nominal, class II and III movement of 50% compression or extension, a 6 in maximum extended opening and a generic metal cover with retaining strap. Confirm current listing scope and the exact PJC pan detail against those requirements.

2HPJC-2-4-MBF floor-to-floor drawing · October 28, 2022 · Barrier, UL listing and minimum slab callouts

FF-D-1138 horizontal joint assembly design · November 1, 2013 · Balco-hosted UL design · Floor Assembly and Joint System items 1–2

Wabo SeismicPan SPJ

Sika Emseal · SPJ-400 · Official product page

Technical evidence for Wabo SeismicPan SPJ (6)
Joint opening
4 in nominal · SPJ family · 2–18 in

Select SPJ-400 in the standard movement table. The compact SPJ-400C is a separate model with a different movement value.

Wabo SeismicPan product data · See product data sheet · Movement Table

Seismic movement
4.75 in total travel · SPJ-400 · total as reported

The table reports total movement without giving opening and closing endpoints. The product family supports lateral shear and vertical displacement. Confirm model-specific directional limits.

Wabo SeismicPan product data · See product data sheet · Description and Movement Table

Wabo SeismicPan SPJ product page · Page revision unstated · Product overview

Traffic and load
150 psf distributed live load · Foot and rolling traffic described

Sika Emseal describes pedestrian and rolling traffic on the flush cover. The numerical load is distributed across the pan. Ask for contact-area and concentrated wheel-load evidence.

Wabo SeismicPan product data · See product data sheet · Description

Wabo SeismicPan SPJ product page · Page revision unstated · Product overview

Installation
Recessed centering-bar pan · Deck-to-deck · concrete blockouts

Recessed edge frames and a seismic centering bar support the pan. Review the deck-to-deck detail for SPJ-400 and coordinate field infill and sealant.

SeismicPan floor conditions · Rev. A · May 1, 2024 · SPJ 400–1800 deck-to-deck condition

Floor finish
Tile, stone, terrazzo and more · Finish infill at the walking surface

The publisher also lists carpet, hardwood, vinyl and concrete. Confirm finish build-up for the selected detail.

Wabo SeismicPan SPJ product page · Page revision unstated · Product overview and Features

Fire documentation
Emshield DFR option · UL 2079 barrier documentation · assembly open

The SPJ page identifies DFR as an add-on and directs users to confirm sizes. DFR2 literature describes the barrier's tested conditions. Verify the listed geometry and movement envelope with the SPJ cover in place.

Wabo SeismicPan SPJ product page · Page revision unstated · Product overview, Emshield DFR option

Emshield DFR2 technical data · See product data sheet · Fire resistance and movement