System 01
Product comparison
Vapor-Permeable Self-Adhered Air Barriers Compared
Compare vapor-permeable self-adhered sheet air barriers with source-attributed ASTM E2178 material evidence. Threshold pass statements stay explicit — no rankings or code-approval claims.
Source checking confirms the cited manufacturer material, not independent testing or product approval.
Comparing 4 published products
System 02
DELTA-VENT SA
System 03
PERM-A-BARRIER VPS 30 Wall Membrane
System 04
WrapShield SA Self-Adhered
Identity
Canonical product and manufacturer relationships.
| Attribute | SOPRASEAL STICK VPSOPREMA | DELTA-VENT SADörken Systems | PERM-A-BARRIER VPS 30 Wall MembraneGCP Applied Technologies | WrapShield SA Self-AdheredVaproShield |
|---|---|---|---|---|
| Product identity and manufacturerSupplemental catalog identity and manufacturer relationship. | SOPRASEAL STICK VP · SOPREMA Source-checked manufacturer specification Official manufacturer product page | DELTA-VENT SA · Dörken Systems Source-checked manufacturer specification Official manufacturer product page | PERM-A-BARRIER VPS 30 Wall Membrane · GCP Applied Technologies Source-checked manufacturer specification Official manufacturer product page | WrapShield SA Self-Adhered · VaproShield Source-checked manufacturer specification Official manufacturer product page |
Product identity and manufacturer
Supplemental catalog identity and manufacturer relationship.
SOPREMASOPRASEAL STICK VP
SOPRASEAL STICK VP · SOPREMA
Source-checked manufacturer specification
Official manufacturer product pageDörken SystemsDELTA-VENT SA
DELTA-VENT SA · Dörken Systems
Source-checked manufacturer specification
Official manufacturer product pageGCP Applied TechnologiesPERM-A-BARRIER VPS 30 Wall Membrane
PERM-A-BARRIER VPS 30 Wall Membrane · GCP Applied Technologies
Source-checked manufacturer specification
Official manufacturer product pageVaproShieldWrapShield SA Self-Adhered
WrapShield SA Self-Adhered · VaproShield
Source-checked manufacturer specification
Official manufacturer product page
Identity and classification
Product family, vapor class, and membrane composition for self-adhered sheet air barriers.
| Attribute | SOPRASEAL STICK VPSOPREMA | DELTA-VENT SADörken Systems | PERM-A-BARRIER VPS 30 Wall MembraneGCP Applied Technologies | WrapShield SA Self-AdheredVaproShield |
|---|---|---|---|---|
| Technical product familySelf-adhered sheet air barrier family only — fluid-applied and mechanically fastened wraps stay out of scope. | Self-adhered sheet air barrier membrane Source-checked manufacturer specification SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market only | Self-adhered sheet air barrier membrane Source-checked manufacturer specification Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American document | Self-adhered sheet air barrier membrane Source-checked manufacturer specification GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use only | Self-adhered sheet air barrier membrane Manufacturer claim VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17 |
| Vapor classificationManufacturer-stated impermeable vs permeable classification, supported by ASTM E96 water-vapor permeance — never by ASTM E2178 air permeance. Prefer cohort-matched matrices for fair comparison. | Vapor permeable air barrier (manufacturer classification; supported by ASTM E96 Procedure A 11 perm / Procedure B 14 perm — not by ASTM E2178) Source-checked manufacturer specification Vapor class is grounded in manufacturer classification plus ASTM E96 water-vapor evidence. Do not infer vapor class from ASTM E2178 air permeance. SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market only | Vapor permeable WRB / air barrier (manufacturer classification; supported by ASTM E96 Procedure A 35 perms / Procedure B 50 perms — not by ASTM E2178) Source-checked manufacturer specification Vapor class is grounded in manufacturer classification plus ASTM E96 water-vapor evidence. Do not infer vapor class from ASTM E2178 air permeance. Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American document | Vapor permeable air and water barrier (manufacturer classification; supported by ASTM E96 Method B 13.9 perms on the reviewed data sheet — Method A not stated on that sheet; not by ASTM E2178) Source-checked manufacturer specification Vapor class is grounded in manufacturer classification plus ASTM E96 water-vapor evidence. Do not infer vapor class from ASTM E2178 air permeance. GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use only | Vapor permeable WRB / air barrier (manufacturer positioning; supported by ASTM E96 Procedure A 40.45 perms / Procedure B 50.45 perms — not by ASTM E2178) Manufacturer claim Vapor class is grounded in manufacturer classification plus ASTM E96 water-vapor evidence. Do not infer vapor class from ASTM E2178 air permeance. VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17 |
| Material compositionMembrane composition as stated on the reviewed manufacturer technical data sheet. | Tri-laminated polypropylene facer with self-adhesive underface covered by silicone release film (manufacturer TDS) Source-checked manufacturer specification SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market only | Three-layer membrane: high-strength spunbonded polypropylene outer layers thermally bonded to a vapor-permeable watertight TPU middle layer, with full-surface pressure-sensitive adhesive (manufacturer TDS) Source-checked manufacturer specification Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American document | Proprietary breathable carrier film with specially designed adhesive; primerless self-adhered vapor-permeable sheet (manufacturer data sheet) Source-checked manufacturer specification GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use only | Self-adhered vapor-permeable water-resistive / air-barrier sheet; orange top face and white back per manufacturer physical-properties table Manufacturer claim VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17 |
| Nominal thicknessPublished nominal thickness only — missing values stay explicit. | 0.6 mm (24 mils) Source-checked manufacturer specification SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market only | Not disclosed in reviewed manufacturer sources Not disclosed Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American document | Not disclosed in reviewed manufacturer sources Not disclosed GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use only | 0.5743 mm (22.61 mil) Manufacturer claim VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17 |
Technical product family
Self-adhered sheet air barrier family only — fluid-applied and mechanically fastened wraps stay out of scope.
SOPREMASOPRASEAL STICK VP
Self-adhered sheet air barrier membrane
Source-checked manufacturer specification
SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market onlyDörken SystemsDELTA-VENT SA
Self-adhered sheet air barrier membrane
Source-checked manufacturer specification
Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American documentGCP Applied TechnologiesPERM-A-BARRIER VPS 30 Wall Membrane
Self-adhered sheet air barrier membrane
Source-checked manufacturer specification
GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use onlyVaproShieldWrapShield SA Self-Adhered
Self-adhered sheet air barrier membrane
Manufacturer claim
VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17
Vapor classification
Manufacturer-stated impermeable vs permeable classification, supported by ASTM E96 water-vapor permeance — never by ASTM E2178 air permeance. Prefer cohort-matched matrices for fair comparison.
SOPREMASOPRASEAL STICK VP
Vapor permeable air barrier (manufacturer classification; supported by ASTM E96 Procedure A 11 perm / Procedure B 14 perm — not by ASTM E2178)
Source-checked manufacturer specification
Vapor class is grounded in manufacturer classification plus ASTM E96 water-vapor evidence. Do not infer vapor class from ASTM E2178 air permeance.
SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market onlyDörken SystemsDELTA-VENT SA
Vapor permeable WRB / air barrier (manufacturer classification; supported by ASTM E96 Procedure A 35 perms / Procedure B 50 perms — not by ASTM E2178)
Source-checked manufacturer specification
Vapor class is grounded in manufacturer classification plus ASTM E96 water-vapor evidence. Do not infer vapor class from ASTM E2178 air permeance.
Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American documentGCP Applied TechnologiesPERM-A-BARRIER VPS 30 Wall Membrane
Vapor permeable air and water barrier (manufacturer classification; supported by ASTM E96 Method B 13.9 perms on the reviewed data sheet — Method A not stated on that sheet; not by ASTM E2178)
Source-checked manufacturer specification
Vapor class is grounded in manufacturer classification plus ASTM E96 water-vapor evidence. Do not infer vapor class from ASTM E2178 air permeance.
GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use onlyVaproShieldWrapShield SA Self-Adhered
Vapor permeable WRB / air barrier (manufacturer positioning; supported by ASTM E96 Procedure A 40.45 perms / Procedure B 50.45 perms — not by ASTM E2178)
Manufacturer claim
Vapor class is grounded in manufacturer classification plus ASTM E96 water-vapor evidence. Do not infer vapor class from ASTM E2178 air permeance.
VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17
Material composition
Membrane composition as stated on the reviewed manufacturer technical data sheet.
SOPREMASOPRASEAL STICK VP
Tri-laminated polypropylene facer with self-adhesive underface covered by silicone release film (manufacturer TDS)
Source-checked manufacturer specification
SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market onlyDörken SystemsDELTA-VENT SA
Three-layer membrane: high-strength spunbonded polypropylene outer layers thermally bonded to a vapor-permeable watertight TPU middle layer, with full-surface pressure-sensitive adhesive (manufacturer TDS)
Source-checked manufacturer specification
Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American documentGCP Applied TechnologiesPERM-A-BARRIER VPS 30 Wall Membrane
Proprietary breathable carrier film with specially designed adhesive; primerless self-adhered vapor-permeable sheet (manufacturer data sheet)
Source-checked manufacturer specification
GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use onlyVaproShieldWrapShield SA Self-Adhered
Self-adhered vapor-permeable water-resistive / air-barrier sheet; orange top face and white back per manufacturer physical-properties table
Manufacturer claim
VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17
Nominal thickness
Published nominal thickness only — missing values stay explicit.
SOPREMASOPRASEAL STICK VP
0.6 mm (24 mils)
Source-checked manufacturer specification
SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market onlyDörken SystemsDELTA-VENT SA
Not disclosed in reviewed manufacturer sources
Not disclosed
Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American documentGCP Applied TechnologiesPERM-A-BARRIER VPS 30 Wall Membrane
Not disclosed in reviewed manufacturer sources
Not disclosed
GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use onlyVaproShieldWrapShield SA Self-Adhered
0.5743 mm (22.61 mil)
Manufacturer claim
VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17
Material performance
Material-level air and vapor permeance with stated test methods and temperature limits.
| Attribute | SOPRASEAL STICK VPSOPREMA | DELTA-VENT SADörken Systems | PERM-A-BARRIER VPS 30 Wall MembraneGCP Applied Technologies | WrapShield SA Self-AdheredVaproShield |
|---|---|---|---|---|
| Material air permeance (ASTM E2178)Material-level air permeance at the stated pressure. Threshold pass statements remain distinct from precise measured values. | 0.0025 L/(s·m²) @ 75 Pa Source-checked manufacturer specification Material claim only. Do not treat this row as ASTM E2357 / CAN/ULC-S742 assembly leakage or as local code compliance. SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market only | Qualified threshold: Pass (< 0.02 L/(s·m²) @ 75 Pa). This is not an exact measured permeance value; a more precise ASTM E2178 result was not stated on the reviewed TDS Source-checked manufacturer specification Qualified ASTM E2178 threshold/pass only — not an exact measured permeance. Do not treat as numerically equivalent to precise E2178 values, and do not substitute assembly ASTM E2357 / CAN/ULC-S742 leakage or local code compliance. Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American document | Qualified threshold: < 0.02 L/(s·m²) @ 75 Pa (0.004 cfm/ft² nominal equivalent). This is a reported upper bound, not an exact measured permeance; the reviewed sheet does not label this result Pass Source-checked manufacturer specification Qualified ASTM E2178 threshold/pass only — not an exact measured permeance. Do not treat as numerically equivalent to precise E2178 values, and do not substitute assembly ASTM E2357 / CAN/ULC-S742 leakage or local code compliance. GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use only | 0.0001 L/(s·m²) @ 75 Pa (manufacturer-reported result). Rounded imperial zero omitted; it does not mean zero leakage Manufacturer claim Material claim only. Do not treat this row as ASTM E2357 / CAN/ULC-S742 assembly leakage or as local code compliance. VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17 |
| Material air permeance test methodTest method and pressure basis published with the material air-permeance result. | ASTM E2178 at 75 Pa Source-checked manufacturer specification SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market only | ASTM E2178; CAN/ULC-S741-08 also cited with the pass threshold Source-checked manufacturer specification Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American document | ASTM E2178 at 75 Pa (1.57 psf) Source-checked manufacturer specification GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use only | ASTM E2178 at 75 Pa Manufacturer claim VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17 |
| Water-vapor permeance (ASTM E96/E96M)A (desiccant/dry cup) and B (water/wet cup) are different conditions. US perm = grain/(h·ft²·inHg). Preserve the cited edition; do not average methods or infer matching temperature/RH. | 629 ng/(Pa·s·m²) (11 perm) Procedure A; 802 ng/(Pa·s·m²) (14 perm) Procedure B Source-checked manufacturer specification SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market only | 35 US perms (ASTM E96-05 Procedure A); 50 US perms (Procedure B). Temperature/RH not stated; inconsistent bracketed grain-unit figures excluded Source-checked manufacturer specification Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American document | 13.9 perms (ASTM E96 Method B, wet cup). Method A / dry-cup permeance was not stated on the reviewed data sheet Source-checked manufacturer specification GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use only | 40.45 US perms (Procedure A / desiccant, 2314 ng/(Pa·s·m²)); 50.45 US perms (Procedure B / water, 2886 ng/(Pa·s·m²)); both at 24.4°C and 50% RH Manufacturer claim VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17 |
| Installation temperature limitsManufacturer-stated application temperature window, including winter/summer grades when published. | -7°C to 40°C (19°F to 104°F) Source-checked manufacturer specification SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market only | Minimum 40°F (5°C) Source-checked manufacturer specification Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American document | Air and surface temperatures above 0°F (-17.78°C) Source-checked manufacturer specification GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use only | Minimum 20°F and rising; PDS table gives -6.6°C, installation text rounds to -6°C Manufacturer claim VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17 |
| Service temperaturePublished in-service temperature range when disclosed. | -40°C to 85°C (-40°F to 185°F) Source-checked manufacturer specification SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market only | -40°F to +176°F (-40°C to +80°C) with primer; -13°F to +176°F (-25°C to +80°C) without primer per reviewed TDS Source-checked manufacturer specification Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American document | Maximum in-service temperature 200°F (93°C); lower bound not stated on the reviewed data sheet Source-checked manufacturer specification GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use only | -40°F to 225°F (-40°C to 107°C) Manufacturer claim VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17 |
| Substrate compatibilitySubstrates listed on the reviewed manufacturer documentation only. | Most substrates such as masonry, concrete, wood, and gypsum (manufacturer recommended substrates) Source-checked manufacturer specification SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market only | Concrete, masonry, OSB, plywood, or exterior grade drywall; primer products listed where required (DELTA-HF PRIMER / DELTA-ADHESIVE family) Source-checked manufacturer specification Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American document | Prepared wall substrates including gypsum (manufacturer notes priming gypsum cut edges to reduce dust) and OSB with PERM-A-BARRIER Adhesive Primer recommended before membrane application (manufacturer data sheet) Source-checked manufacturer specification GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use only | Peel-adhesion substrates documented on the product page include DensGlass Gold, plywood, concrete, and CMU (no peeling, buckling, or ripping in the reviewed adhesion table) Manufacturer claim VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17 |
| CAN/ULC-S741 material statementOnly when the reviewed document explicitly states S741 material permeance or conformance language. | Air permeance of membrane CAN/ULC S741 < 0.001 L/(s·m²) on the reviewed TDS Source-checked manufacturer specification SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market only | CAN/ULC-S741-08 cited with ASTM E2178 pass (< 0.02 L/(s·m²) @ 75 Pa) on the reviewed TDS Source-checked manufacturer specification Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American document | Not disclosed in reviewed manufacturer sources Not disclosed GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use only | Not disclosed in reviewed manufacturer sources Not disclosed VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17 |
Material air permeance (ASTM E2178)
Material-level air permeance at the stated pressure. Threshold pass statements remain distinct from precise measured values.
SOPREMASOPRASEAL STICK VP
0.0025 L/(s·m²) @ 75 Pa
Source-checked manufacturer specification
Material claim only. Do not treat this row as ASTM E2357 / CAN/ULC-S742 assembly leakage or as local code compliance.
SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market onlyDörken SystemsDELTA-VENT SA
Qualified threshold: Pass (< 0.02 L/(s·m²) @ 75 Pa). This is not an exact measured permeance value; a more precise ASTM E2178 result was not stated on the reviewed TDS
Source-checked manufacturer specification
Qualified ASTM E2178 threshold/pass only — not an exact measured permeance. Do not treat as numerically equivalent to precise E2178 values, and do not substitute assembly ASTM E2357 / CAN/ULC-S742 leakage or local code compliance.
Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American documentGCP Applied TechnologiesPERM-A-BARRIER VPS 30 Wall Membrane
Qualified threshold: < 0.02 L/(s·m²) @ 75 Pa (0.004 cfm/ft² nominal equivalent). This is a reported upper bound, not an exact measured permeance; the reviewed sheet does not label this result Pass
Source-checked manufacturer specification
Qualified ASTM E2178 threshold/pass only — not an exact measured permeance. Do not treat as numerically equivalent to precise E2178 values, and do not substitute assembly ASTM E2357 / CAN/ULC-S742 leakage or local code compliance.
GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use onlyVaproShieldWrapShield SA Self-Adhered
0.0001 L/(s·m²) @ 75 Pa (manufacturer-reported result). Rounded imperial zero omitted; it does not mean zero leakage
Manufacturer claim
Material claim only. Do not treat this row as ASTM E2357 / CAN/ULC-S742 assembly leakage or as local code compliance.
VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17
Material air permeance test method
Test method and pressure basis published with the material air-permeance result.
SOPREMASOPRASEAL STICK VP
ASTM E2178 at 75 Pa
Source-checked manufacturer specification
SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market onlyDörken SystemsDELTA-VENT SA
ASTM E2178; CAN/ULC-S741-08 also cited with the pass threshold
Source-checked manufacturer specification
Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American documentGCP Applied TechnologiesPERM-A-BARRIER VPS 30 Wall Membrane
ASTM E2178 at 75 Pa (1.57 psf)
Source-checked manufacturer specification
GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use onlyVaproShieldWrapShield SA Self-Adhered
ASTM E2178 at 75 Pa
Manufacturer claim
VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17
Water-vapor permeance (ASTM E96/E96M)
A (desiccant/dry cup) and B (water/wet cup) are different conditions. US perm = grain/(h·ft²·inHg). Preserve the cited edition; do not average methods or infer matching temperature/RH.
SOPREMASOPRASEAL STICK VP
629 ng/(Pa·s·m²) (11 perm) Procedure A; 802 ng/(Pa·s·m²) (14 perm) Procedure B
Source-checked manufacturer specification
SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market onlyDörken SystemsDELTA-VENT SA
35 US perms (ASTM E96-05 Procedure A); 50 US perms (Procedure B). Temperature/RH not stated; inconsistent bracketed grain-unit figures excluded
Source-checked manufacturer specification
Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American documentGCP Applied TechnologiesPERM-A-BARRIER VPS 30 Wall Membrane
13.9 perms (ASTM E96 Method B, wet cup). Method A / dry-cup permeance was not stated on the reviewed data sheet
Source-checked manufacturer specification
GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use onlyVaproShieldWrapShield SA Self-Adhered
40.45 US perms (Procedure A / desiccant, 2314 ng/(Pa·s·m²)); 50.45 US perms (Procedure B / water, 2886 ng/(Pa·s·m²)); both at 24.4°C and 50% RH
Manufacturer claim
VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17
Installation temperature limits
Manufacturer-stated application temperature window, including winter/summer grades when published.
SOPREMASOPRASEAL STICK VP
-7°C to 40°C (19°F to 104°F)
Source-checked manufacturer specification
SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market onlyDörken SystemsDELTA-VENT SA
Minimum 40°F (5°C)
Source-checked manufacturer specification
Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American documentGCP Applied TechnologiesPERM-A-BARRIER VPS 30 Wall Membrane
Air and surface temperatures above 0°F (-17.78°C)
Source-checked manufacturer specification
GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use onlyVaproShieldWrapShield SA Self-Adhered
Minimum 20°F and rising; PDS table gives -6.6°C, installation text rounds to -6°C
Manufacturer claim
VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17
Service temperature
Published in-service temperature range when disclosed.
SOPREMASOPRASEAL STICK VP
-40°C to 85°C (-40°F to 185°F)
Source-checked manufacturer specification
SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market onlyDörken SystemsDELTA-VENT SA
-40°F to +176°F (-40°C to +80°C) with primer; -13°F to +176°F (-25°C to +80°C) without primer per reviewed TDS
Source-checked manufacturer specification
Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American documentGCP Applied TechnologiesPERM-A-BARRIER VPS 30 Wall Membrane
Maximum in-service temperature 200°F (93°C); lower bound not stated on the reviewed data sheet
Source-checked manufacturer specification
GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use onlyVaproShieldWrapShield SA Self-Adhered
-40°F to 225°F (-40°C to 107°C)
Manufacturer claim
VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17
Substrate compatibility
Substrates listed on the reviewed manufacturer documentation only.
SOPREMASOPRASEAL STICK VP
Most substrates such as masonry, concrete, wood, and gypsum (manufacturer recommended substrates)
Source-checked manufacturer specification
SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market onlyDörken SystemsDELTA-VENT SA
Concrete, masonry, OSB, plywood, or exterior grade drywall; primer products listed where required (DELTA-HF PRIMER / DELTA-ADHESIVE family)
Source-checked manufacturer specification
Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American documentGCP Applied TechnologiesPERM-A-BARRIER VPS 30 Wall Membrane
Prepared wall substrates including gypsum (manufacturer notes priming gypsum cut edges to reduce dust) and OSB with PERM-A-BARRIER Adhesive Primer recommended before membrane application (manufacturer data sheet)
Source-checked manufacturer specification
GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use onlyVaproShieldWrapShield SA Self-Adhered
Peel-adhesion substrates documented on the product page include DensGlass Gold, plywood, concrete, and CMU (no peeling, buckling, or ripping in the reviewed adhesion table)
Manufacturer claim
VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17
CAN/ULC-S741 material statement
Only when the reviewed document explicitly states S741 material permeance or conformance language.
SOPREMASOPRASEAL STICK VP
Air permeance of membrane CAN/ULC S741 < 0.001 L/(s·m²) on the reviewed TDS
Source-checked manufacturer specification
SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market onlyDörken SystemsDELTA-VENT SA
CAN/ULC-S741-08 cited with ASTM E2178 pass (< 0.02 L/(s·m²) @ 75 Pa) on the reviewed TDS
Source-checked manufacturer specification
Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American documentGCP Applied TechnologiesPERM-A-BARRIER VPS 30 Wall Membrane
Not disclosed in reviewed manufacturer sources
Not disclosed
GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use onlyVaproShieldWrapShield SA Self-Adhered
Not disclosed in reviewed manufacturer sources
Not disclosed
VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17
Source register
Document editions, market applicability, and qualifications for preliminary specification research.
| Attribute | SOPRASEAL STICK VPSOPREMA | DELTA-VENT SADörken Systems | PERM-A-BARRIER VPS 30 Wall MembraneGCP Applied Technologies | WrapShield SA Self-AdheredVaproShield |
|---|---|---|---|---|
| Document version and qualificationsEvidence review: 2026-11-17. Document dates are not test dates. Market applicability and unresolved source limitations remain explicit. | TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market only Manufacturer claim All TDS values are nominal. E96 temperature/RH not stated. Primer may be needed for jobsite conditions; follow current detailing instructions. Official manufacturer document | Technical Data Sheet dated 2025-04-15; North American document Manufacturer claim ASTM E96-05 Procedures A/B; temperature/RH not stated. Inconsistent bracketed grain-unit figures are excluded; retain the stated perm values. Confirm primer and accessory compatibility. Official manufacturer document | Online data sheet last updated 2026-06-23; valid for United States use only Manufacturer claim E96 Method B only; temperature/RH and Method A not stated. Installation section requires air and surface temperatures above 0°F; the overview says at or above. Confirm the boundary with GCP. OSB primer recommended. Official manufacturer document | Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17 Manufacturer claim Direct retrieval returned HTTP 403; official indexed PDF reviewed, current revision not independently confirmed. E96 A/B: 24.4°C, 50% RH. E2357 imperial limits differ between PDF and web table and are not equivalent to the SI limit; only the shared SI value is retained. Confirm current data with VaproShield. A ventilated vertical drainage cavity is required. Official manufacturer document |
Document version and qualifications
Evidence review: 2026-11-17. Document dates are not test dates. Market applicability and unresolved source limitations remain explicit.
SOPREMASOPRASEAL STICK VP
TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market only
Manufacturer claim
All TDS values are nominal. E96 temperature/RH not stated. Primer may be needed for jobsite conditions; follow current detailing instructions.
Official manufacturer documentDörken SystemsDELTA-VENT SA
Technical Data Sheet dated 2025-04-15; North American document
Manufacturer claim
ASTM E96-05 Procedures A/B; temperature/RH not stated. Inconsistent bracketed grain-unit figures are excluded; retain the stated perm values. Confirm primer and accessory compatibility.
Official manufacturer documentGCP Applied TechnologiesPERM-A-BARRIER VPS 30 Wall Membrane
Online data sheet last updated 2026-06-23; valid for United States use only
Manufacturer claim
E96 Method B only; temperature/RH and Method A not stated. Installation section requires air and surface temperatures above 0°F; the overview says at or above. Confirm the boundary with GCP. OSB primer recommended.
Official manufacturer documentVaproShieldWrapShield SA Self-Adhered
Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17
Manufacturer claim
Direct retrieval returned HTTP 403; official indexed PDF reviewed, current revision not independently confirmed. E96 A/B: 24.4°C, 50% RH. E2357 imperial limits differ between PDF and web table and are not equivalent to the SI limit; only the shared SI value is retained. Confirm current data with VaproShield. A ventilated vertical drainage cavity is required.
Official manufacturer document
Assembly evidence
Assembly air leakage and NFPA 285 notes kept separate from material ASTM E2178 cells.
| Attribute | SOPRASEAL STICK VPSOPREMA | DELTA-VENT SADörken Systems | PERM-A-BARRIER VPS 30 Wall MembraneGCP Applied Technologies | WrapShield SA Self-AdheredVaproShield |
|---|---|---|---|---|
| Assembly air leakage evidenceASTM E2357 / CAN/ULC-S742 and related assembly statements. Never interchangeable with material ASTM E2178 cells. | ASTM E2357 air leakage resistance < 0.005 L/(s·m²) @ 75 Pa on the reviewed TDS; product is noted as part of a ULC-S742 tested wall system — assembly evidence remains separate from material E2178 Source-checked manufacturer specification Assembly claim class. Confirm the tested assembly configuration; do not transfer assembly leakage to the material row. SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market only | ASTM E2357 < 0.2 L/(s·m²) @ 75 Pa; CAN/ULC-S742-11 Class A1 on the reviewed TDS — assembly claim class, not material E2178 Source-checked manufacturer specification Assembly claim class. Confirm the tested assembly configuration; do not transfer assembly leakage to the material row. Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American document | ASTM E2357 assembly air permeance < 0.2 L/(s·m²) @ 75 Pa (< 0.04 cfm/ft²) on the reviewed data sheet — assembly evidence remains separate from material ASTM E2178 Source-checked manufacturer specification Assembly claim class. Confirm the tested assembly configuration; do not transfer assembly leakage to the material row. GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use only | ASTM E2357 reported upper bound < 0.01 L/(s·m²) @ 75 Pa. Imperial limits conflict between official PDF and web table and are omitted pending manufacturer clarification. CAN/ULC-S742-11 Classification A1 Pass is a separate assembly statement Manufacturer claim Assembly claim class. Confirm the tested assembly configuration; do not transfer assembly leakage to the material row. VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17 |
| NFPA 285 assembly noteAssembly-specific fire-propagation context — not a standalone membrane property. | Component of an assembly tested in conformity with NFPA 285 (Pass) — assembly-specific Source-checked manufacturer specification Assembly listing confirmation remains project-specific. SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market only | NFPA 285 compliance is claimed on the manufacturer product page as assembly context; confirm the current listed assemblies before specification — not captured as a material-alone numeric property on the reviewed TDS table Source-checked manufacturer specification Assembly listing confirmation remains project-specific. Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American document | Pass as part of various wall assemblies with foam plastic insulation — assembly-specific; confirm current listed assemblies before specification Source-checked manufacturer specification Assembly listing confirmation remains project-specific. GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use only | Manufacturer states NFPA 285 compliant assemblies are available (50+ listed assemblies referenced on the product page) — confirm the specific assembly listing; not a material-alone numeric property Manufacturer claim Assembly listing confirmation remains project-specific. VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17 |
Assembly air leakage evidence
ASTM E2357 / CAN/ULC-S742 and related assembly statements. Never interchangeable with material ASTM E2178 cells.
SOPREMASOPRASEAL STICK VP
ASTM E2357 air leakage resistance < 0.005 L/(s·m²) @ 75 Pa on the reviewed TDS; product is noted as part of a ULC-S742 tested wall system — assembly evidence remains separate from material E2178
Source-checked manufacturer specification
Assembly claim class. Confirm the tested assembly configuration; do not transfer assembly leakage to the material row.
SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market onlyDörken SystemsDELTA-VENT SA
ASTM E2357 < 0.2 L/(s·m²) @ 75 Pa; CAN/ULC-S742-11 Class A1 on the reviewed TDS — assembly claim class, not material E2178
Source-checked manufacturer specification
Assembly claim class. Confirm the tested assembly configuration; do not transfer assembly leakage to the material row.
Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American documentGCP Applied TechnologiesPERM-A-BARRIER VPS 30 Wall Membrane
ASTM E2357 assembly air permeance < 0.2 L/(s·m²) @ 75 Pa (< 0.04 cfm/ft²) on the reviewed data sheet — assembly evidence remains separate from material ASTM E2178
Source-checked manufacturer specification
Assembly claim class. Confirm the tested assembly configuration; do not transfer assembly leakage to the material row.
GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use onlyVaproShieldWrapShield SA Self-Adhered
ASTM E2357 reported upper bound < 0.01 L/(s·m²) @ 75 Pa. Imperial limits conflict between official PDF and web table and are omitted pending manufacturer clarification. CAN/ULC-S742-11 Classification A1 Pass is a separate assembly statement
Manufacturer claim
Assembly claim class. Confirm the tested assembly configuration; do not transfer assembly leakage to the material row.
VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17
NFPA 285 assembly note
Assembly-specific fire-propagation context — not a standalone membrane property.
SOPREMASOPRASEAL STICK VP
Component of an assembly tested in conformity with NFPA 285 (Pass) — assembly-specific
Source-checked manufacturer specification
Assembly listing confirmation remains project-specific.
SOPREMA SOPRASEAL STICK VP technical data sheet · TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market onlyDörken SystemsDELTA-VENT SA
NFPA 285 compliance is claimed on the manufacturer product page as assembly context; confirm the current listed assemblies before specification — not captured as a material-alone numeric property on the reviewed TDS table
Source-checked manufacturer specification
Assembly listing confirmation remains project-specific.
Dörken DELTA-VENT SA technical data sheet · Technical Data Sheet dated 2025-04-15; North American documentGCP Applied TechnologiesPERM-A-BARRIER VPS 30 Wall Membrane
Pass as part of various wall assemblies with foam plastic insulation — assembly-specific; confirm current listed assemblies before specification
Source-checked manufacturer specification
Assembly listing confirmation remains project-specific.
GCP PERM-A-BARRIER VPS 30 wall membrane data sheet · Online data sheet last updated 2026-06-23; valid for United States use onlyVaproShieldWrapShield SA Self-Adhered
Manufacturer states NFPA 285 compliant assemblies are available (50+ listed assemblies referenced on the product page) — confirm the specific assembly listing; not a material-alone numeric property
Manufacturer claim
Assembly listing confirmation remains project-specific.
VaproShield WrapShield SA product data sheet · Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17
Fabrication and project delivery
Published size, fabrication, installation, and evidence limits that require project-specific coordination.
| Attribute | SOPRASEAL STICK VPSOPREMA | DELTA-VENT SADörken Systems | PERM-A-BARRIER VPS 30 Wall MembraneGCP Applied Technologies | WrapShield SA Self-AdheredVaproShield |
|---|---|---|---|---|
| Document version and qualificationsEvidence review: 2026-11-17. Document dates are not test dates. Market applicability and unresolved source limitations remain explicit. | TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market only Manufacturer claim All TDS values are nominal. E96 temperature/RH not stated. Primer may be needed for jobsite conditions; follow current detailing instructions. Official manufacturer document | Technical Data Sheet dated 2025-04-15; North American document Manufacturer claim ASTM E96-05 Procedures A/B; temperature/RH not stated. Inconsistent bracketed grain-unit figures are excluded; retain the stated perm values. Confirm primer and accessory compatibility. Official manufacturer document | Online data sheet last updated 2026-06-23; valid for United States use only Manufacturer claim E96 Method B only; temperature/RH and Method A not stated. Installation section requires air and surface temperatures above 0°F; the overview says at or above. Confirm the boundary with GCP. OSB primer recommended. Official manufacturer document | Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17 Manufacturer claim Direct retrieval returned HTTP 403; official indexed PDF reviewed, current revision not independently confirmed. E96 A/B: 24.4°C, 50% RH. E2357 imperial limits differ between PDF and web table and are not equivalent to the SI limit; only the shared SI value is retained. Confirm current data with VaproShield. A ventilated vertical drainage cavity is required. Official manufacturer document |
Document version and qualifications
Evidence review: 2026-11-17. Document dates are not test dates. Market applicability and unresolved source limitations remain explicit.
SOPREMASOPRASEAL STICK VP
TDS 260408SCANE (2026-04-08), supersedes 250728SCANE; Canadian market only
Manufacturer claim
All TDS values are nominal. E96 temperature/RH not stated. Primer may be needed for jobsite conditions; follow current detailing instructions.
Official manufacturer documentDörken SystemsDELTA-VENT SA
Technical Data Sheet dated 2025-04-15; North American document
Manufacturer claim
ASTM E96-05 Procedures A/B; temperature/RH not stated. Inconsistent bracketed grain-unit figures are excluded; retain the stated perm values. Confirm primer and accessory compatibility.
Official manufacturer documentGCP Applied TechnologiesPERM-A-BARRIER VPS 30 Wall Membrane
Online data sheet last updated 2026-06-23; valid for United States use only
Manufacturer claim
E96 Method B only; temperature/RH and Method A not stated. Installation section requires air and surface temperatures above 0°F; the overview says at or above. Confirm the boundary with GCP. OSB primer recommended.
Official manufacturer documentVaproShieldWrapShield SA Self-Adhered
Product Data Sheet footer 03/04/26; product 24109090; official indexed copy reviewed 2026-11-17
Manufacturer claim
Direct retrieval returned HTTP 403; official indexed PDF reviewed, current revision not independently confirmed. E96 A/B: 24.4°C, 50% RH. E2357 imperial limits differ between PDF and web table and are not equivalent to the SI limit; only the shared SI value is retained. Confirm current data with VaproShield. A ventilated vertical drainage cavity is required.
Official manufacturer document
Decision-support distinctions
Evidence-backed differences that help frame evaluation. These are not rankings, scores, or purchase recommendations.
This matrix is limited to one vapor class so ASTM E96 drying behavior is not mixed with the opposite cohort. Open manufacturer technical data sheets for primer, UV, and detailing requirements.
Material ASTM E2178 values and assembly ASTM E2357 / CAN/ULC-S742 statements remain separate evidence rows. Technical comparability does not establish jurisdiction compliance or product approval.
Comparison limitations
Boundaries that keep manufacturer-attributed evidence from being overstated.
- All quantitative claims are manufacturer-reported from reviewed technical data sheets; they are not independent laboratory retests.
- Material air permeance (ASTM E2178 / material CAN/ULC-S741 statements) and assembly air leakage (ASTM E2357 / CAN/ULC-S742) are different claim classes and are never substituted for each other.
- Vapor-impermeable and vapor-permeable sheets serve different drying strategies; cohort matrices stay separate even when both appear in the category workspace.
- Threshold “Pass (< limit)” air-permeance statements are not identical to precise measured values.
- NFPA 285 and other fire-propagation results belong to tested wall assemblies, not to membranes in isolation.
- Technical product comparability does not establish local code compliance, AHJ acceptance, or product approval in any jurisdiction.
- Installation primers, substrate preparation, UV exposure limits, and detailing accessories remain in current manufacturer instructions.
- Pricing, lead times, installer rankings, and total cost of ownership are not invented.
- No ranking, score, or preferred-product recommendation is computed.