EverGuard PVC Smooth 60 mil
- Why it surfaced
- The 60-mil smooth membrane is named separately from PVC XK. C(1) is a fully adhered, insulated steel-deck assembly with −45 psf maximum design pressure and general limitation 7.
- Published evidence
Nexus Pavilion · Decision Intelligence
Find published evidence and compare 6 60-mil low-slope membranes.
Florida steel-deck listings that name the 60-mil membrane and can be used as preliminary references.
High-wind exposure. 2 variants with relevant documentation. 4 unassessed.
Global Construction Network (GCN), operated by Nexus Pavilion Inc., provides informational research, product comparisons and decision support based on published manufacturer documentation and identified third-party sources.
Technical specifications and performance values attributed to manufacturers are manufacturer-reported. GCN does not independently test or certify products, guarantee their performance, or warrant the accuracy, completeness or currency of third-party information.
Search results, comparisons and screening outputs are intended to support preliminary research and do not constitute engineering advice, professional certification, regulatory approval or confirmation of project-specific suitability.
Users must independently verify current specifications, product configurations, manufacturer requirements and applicable regulations before making specification, purchasing or installation decisions.
Third-party intellectual property remains subject to its respective owners' rights. References to manufacturers and products do not imply endorsement, sponsorship or affiliation.
Use of GCN is subject to the applicable Nexus Pavilion Inc. Terms of Use.
Values retain their reported basis. Different test methods or conditions limit direct comparison.
Scroll across to compare all 6 membranes.
| Criterion | TPO | PVC | ||||
|---|---|---|---|---|---|---|
| EverGuard TPO Smooth 60 milGAF | JM TPO 60 milJohns Manville | UltraPly TPO 60 milElevate | Sure-Weld Reinforced TPO 60 milCarlisle SynTec | EverGuard PVC Smooth 60 milGAF | JM PVC SD Plus 60 milJohns Manville | |
| Nominal thicknessShared dimensional designation. | 0.060 in Nominal Source Details0.060 in · 1.524 mm nominal. ASTM D751. Published nominal designation. Assessed only as a dimensional designation. COMEG876-PDF-0726 · Physical / Additional Properties, 60 mil column, white-only footnote; guarantee and roll-size tables | 0.060 in Nominal Source Details0.060 in · 1.524 mm nominal. ASTM D751. Published nominal designation. Assessed only as a dimensional designation. RS-8633 8-21, replaces 4-21 · pp. 1–2, Packaging and Dimensions; Tested Physical Properties; Supplemental Testing | 0.060 ±10% in Nominal Source Details0.060 ±10% in · 1.524 mm nominal. ASTM D751. Published nominal designation. Assessed only as a dimensional designation. TIS 201 · 2026-10-14 · pp. 1–4, description, environmental metrics, Typical Properties 60-mil column and product sizes | 60 ±10% mil Nominal Source Details60 ±10% mil · 1.524 mm nominal. ASTM D751. Published nominal designation. Assessed only as a dimensional designation. 01.28.26 · pp. 1 and 4, overview and Typical Properties, 60-mil column; radiative table | 60 mil Nominal Source Details60 mil · 1.52 mm nominal. ASTM D751. Overall thickness, 60-mil column. GAF reports approximate guide values subject to manufacturing variation. COMEG992-PDF-0426 · p. 2, Physical Properties, Overall Thickness, 60-mil column | 0.060 in Nominal Source Details0.060 in · 1.524 mm nominal. ASTM D751. Published nominal designation. Assessed only as a dimensional designation. RS-8018 10-25, replaces 5-24 · pp. 1–2, Manufactured Physical Properties; Guarantee and Packaging tables |
| Reported seam strengthPreserve the method and specimen. | 145 lbf Approximate · Factory seam Source Details145 lbf approximate test result. ASTM D751. Factory seam; membrane failure. GAF also prints 645 N. Field-weld acceptance requires separate evidence. COMEG876-PDF-0726 · p. 2, Physical Properties, nominal 60-mil column | 112 lbf Typical · Factory seam Source Details112 lbf typical/average. ASTM D751. Factory seam result; JM also prints 498 N. The row is labeled minimum; the document qualifies the result as a typical average. RS-8633 8-21, replaces 4-21 · p. 2, Tested Physical Properties, JM TPO 60-mil result | Unassessed | 66 lbf Listed minimum · Factory seam Source Details66 lbf listed minimum. ASTM D751 Grab Method. Factory seam minimum; Carlisle prints 290 N. A separate typical factory seam result is unstated. 01.28.26 · p. 4, Typical Properties, requirement and 60-mil columns | 106.40% Approximate · Factory seam · percentage basis unstated Source Details106.40 % approximate test result. ASTM D751. Reported factory seam percentage; table lists a 75% requirement and does not name the denominator. Field-weld acceptance requires separate evidence. COMEG992-PDF-0426 · p. 2, Physical Properties, 60-mil column | 80% Typical · Of breaking strength · seam type unstated Source Details80 % of breaking strength typical/average. ASTM D751. Manufacturer's seam result; 75% is the requirement shown. Factory versus field is unstated. Row labeled minimum; source qualifies its results as typical averages. RS-8018 10-25, replaces 5-24 · p. 2, Manufactured Physical Properties, 60-mil result |
| Low-temperature flexibilityRetain the test temperature and condition. | Unassessed | Pass at −40 °F D2137 brittleness · Pass/fail Source DetailsPass at −40 °F · -40 °C pass/fail. ASTM D2137. RS-8633 p. 2, brittleness point threshold. Distinct from the ASTM D2136 bend test. RS-8633 8-21, replaces 4-21 · pp. 1–2, Packaging and Dimensions; Tested Physical Properties; Supplemental Testing | Pass at −40 °F D2137 brittleness · Pass/fail Source DetailsPass at −40 °F · -40 °C pass/fail. ASTM D2137. Brittleness point; distinct from ASTM D2136 low-temperature bend. TIS 201 · 2026-10-14 · pp. 1–4, description, environmental metrics, Typical Properties 60-mil column and product sizes | −50 °F D2137 brittleness · Typical Source Details−50 °F · -45.556 °C typical. ASTM D2137. Brittleness point; distinct from ASTM D2136 low-temperature bend. 01.28.26 · pp. 1 and 4, overview and Typical Properties, 60-mil column; radiative table | Pass at −40 °F D2136 bend · Pass/fail Source DetailsPass at −40 °F pass/fail. ASTM D2136. Low-temperature bend; not installation temperature. COMEG992-PDF-0426 · p. 2, Physical Properties, Low-Temperature Bend, 60-mil column | Pass at −40 °F D2136 bend · Pass/fail Source DetailsPass at −40 °F pass/fail. ASTM D2136. Low-temperature bend; not installation temperature. RS-8018 10-25, replaces 5-24 · pp. 1–2, Manufactured Physical Properties; Guarantee and Packaging tables |
| Water absorption or immersionRetain the method and basis. | 0.7% D471 · Approximate · Time and temperature unstated Source Details0.7 % approximate test result. ASTM D471. Water absorption; exposure duration and temperature are unstated. COMEG876-PDF-0726 · p. 2, Physical Properties, nominal 60-mil column | 0.11% D471 · Typical · Time and temperature unstated Source Details0.11 % typical/average. ASTM D471. Water absorption result under a maximum-labeled row; JM qualifies its results as typical averages. Exposure duration and temperature are unstated. RS-8633 8-21, replaces 4-21 · p. 2, Tested Physical Properties, JM TPO 60-mil result | <1% D471 · Reported upper bound · Time and temperature unstated Source Details<1 % typical upper bound. ASTM D471. Water absorption for the 60-mil column. The less-than figure is a reported upper bound. Exposure duration and temperature are unstated. TIS 201 · 2026-10-14 · p. 3, Typical Properties, 60-mil Water Absorption | 0.90% D471 · Typical · 166 h at 158 °F · top surface only Source Details0.90 % typical/average. ASTM D471. Water absorption by mass after top-surface water exposure for 166 hours at 158 °F. The table separately lists a ±3.0% maximum. 01.28.26 · p. 4, Typical Properties, requirement and 60-mil columns | 1% D570 · Approximate · Time and temperature unstated Source Details1 % approximate test result. ASTM D570. Weight change after water immersion; exposure duration and temperature are unstated. COMEG992-PDF-0426 · p. 2, Physical Properties, 60-mil column | 3.0% D570 modified · Typical · Time and temperature unstated Source Details3.0 % typical/average. ASTM D570 modified. Reported weight change after immersion equals the stated 3.0% maximum. The modified procedure, duration and temperature are unstated. RS-8018 10-25, replaces 5-24 · p. 2, Manufactured Physical Properties, 60-mil result |
| Attachment and weldsCheck the instructions for the exact system. | Mechanical, induction or adhered Heat-welded seams Source DetailsMechanically attached, induction welded or adhered; heat-welded seams manufacturer-reported. Installation and Features. For adhered systems select one of the listed GAF adhesives and follow the applicable system instructions. COMEG876-PDF-0726 · p. 1, Installation and Features | Adhered or mechanical Hot-air welded seams Source DetailsAdhered or mechanically fastened; hot-air welded seams manufacturer-reported. Installation/Application and System Compatibility. Follow JM TPO application guides and detail drawings. Excluded from multi-ply systems. RS-8633 8-21, replaces 4-21 · p. 1, Installation/Application and System Compatibility | Overlapped laps Heat-welded seams Source DetailsOverlap side and end laps and heat-weld seams manufacturer-reported. Method of Application. Elevate calls for a smooth, dry substrate with contaminants and sharp projections removed. The cited instructions call for repairing rough areas and filling openings wider than ¼ in (6.3 mm in the source). Consult the current Elevate specifications. TIS 201 · 2026-10-14 · p. 1, Method of Application | Adhered, mechanical or induction Hot-air welded laps Source DetailsFully adhered, mechanically fastened or induction welded; hot-air welded laps manufacturer-reported. Installation. The Carlisle system details identify the adhesives, plates or fasteners for each attachment method. The sheet specifies Carlisle Weathered Membrane Cleaner for weather-exposed membrane before welding. Consult the applicable details. 01.28.26 · p. 2, Installation | Mechanical, induction or adhered RhinoBond for induction · heat-welded seams Source DetailsMechanically attached, RhinoBond induction welded or adhered; heat-welded seams manufacturer-reported. Application and Features. The PDS lists EverGuard #2331 Bonding Adhesive, PVC Quick Spray and PVC Quick Lay for adhered applications. Follow the specific GAF system instructions. COMEG992-PDF-0426 · p. 1, Application and Features | Mechanical or fully adhered Hot-air welded seams Source DetailsMechanically fastened or fully adhered; hot-air welded seams manufacturer-reported. Installation/Application and Codes and Approvals. Install cap side up using the lap line and production code to identify it. Follow JM's application guides and details. Excluded from multi-ply systems. RS-8018 10-25, replaces 5-24 · p. 1, Installation/Application, Codes and Approvals and System Compatibility |
| Manufacturer warrantyConfirm system eligibility and exclusions. | Up to 25 years Eligible 60-mil systems Source DetailsUp to 25 years for eligible 60-mil roof systems manufacturer-reported. GAF system guarantee. Additional requirements apply. Fungi and other biological growth are excluded. Confirm the applicable guarantee and its coverage. COMEG876-PDF-0726 · pp. 1–2, Features, footnotes and Available Guarantees | 5, 10, 15 or 20 years Peak Advantage · NDL unstated Source Details5, 10, 15 or 20 years under Peak Advantage manufacturer-reported. Peak Advantage Guarantee Information. The term table gives no no-dollar-limit designation. Standard sale terms include a limited warranty and limitation of remedy. Confirm the issued system guarantee and coverage. RS-8633 8-21, replaces 4-21 · p. 1, Peak Advantage Guarantee Information; p. 2, standard Terms and Conditions | Unassessed | Duration unstated Color fading excluded Source DetailsCarlisle warranty excludes color fading manufacturer-reported. Precautions. The retained PDS gives no warranty duration for the standard reinforced 60-mil sheet. Confirm duration and coverage for the proposed assembly. 01.28.26 · p. 2, Precautions | Up to 30 years Qualified PVC systems · family-level Source DetailsUp to 30 years for qualified PVC systems manufacturer-reported. GAF system guarantee. System-family maximum; the sheet gives no 60-mil-specific term. Conditions apply. Chemical exposure, grease, animal fats and jet fuel are excluded. COMEG992-PDF-0426 · p. 1, Features and guarantee footnotes | 5, 10, 15 or 20 years NDL · eligible mechanical or adhered systems Source Details5, 10, 15 or 20 years NDL for eligible mechanically fastened or adhered systems. Mixed SD Plus/PVC (KEE) jobs excluded. manufacturer-reported. Product documentation. Confirm eligibility for the submitted configuration and obtain the actual guarantee. Standard sale terms include a limited warranty and limitation of remedy. RS-8018 10-25, replaces 5-24 · p. 1, Peak Advantage Guarantee Information; p. 2, standard Terms and Conditions |
88 source-linked specifications from the published GCN catalog.
TPO roofing membrane. Smooth reinforced sheet, nominal 60 mil; reference color white where applicable.
GAF Materials LLC · Official product page
ASTM D751. Published nominal designation. Assessed only as a dimensional designation.
COMEG876-PDF-0726 · Physical / Additional Properties, 60 mil column, white-only footnote; guarantee and roll-size tables
Approximate white-membrane values. Separate minimum-60 variant is also offered.
ASTM D7635. White membrane; GAF labels coating thickness nominal.
COMEG876-PDF-0726 · Physical / Additional Properties, 60 mil column, white-only footnote; guarantee and roll-size tables
Approximate white-membrane values. Separate minimum-60 variant is also offered.
ASTM D751 Grab Method. White; MD × CMD as displayed in PDS.
COMEG876-PDF-0726 · Physical / Additional Properties, 60 mil column, white-only footnote; guarantee and roll-size tables
Approximate white-membrane values. Separate minimum-60 variant is also offered.
ASTM D751. White; direction unspecified in this row.
COMEG876-PDF-0726 · Physical / Additional Properties, 60 mil column, white-only footnote; guarantee and roll-size tables
Approximate white-membrane values. Separate minimum-60 variant is also offered.
ASTM D751. White; 8 × 8 in specimen; MD × CMD.
COMEG876-PDF-0726 · Physical / Additional Properties, 60 mil column, white-only footnote; guarantee and roll-size tables
Approximate white-membrane values. Separate minimum-60 variant is also offered.
ASTM D1204. White; cycle not stated in row.
COMEG876-PDF-0726 · Physical / Additional Properties, 60 mil column, white-only footnote; guarantee and roll-size tables
Approximate white-membrane values. Separate minimum-60 variant is also offered.
ASTM D5635. White; direction and endpoint detail not stated.
COMEG876-PDF-0726 · Physical / Additional Properties, 60 mil column, white-only footnote; guarantee and roll-size tables
Approximate white-membrane values. Separate minimum-60 variant is also offered.
ASTM G155. 340 nm; other settings not verified.
COMEG876-PDF-0726 · Physical / Additional Properties, 60 mil column, white-only footnote; guarantee and roll-size tables
Approximate white-membrane values. Separate minimum-60 variant is also offered.
Product documentation. 100 ft length in the nominal 60-mil roll-size table.
COMEG876-PDF-0726 · Physical / Additional Properties, 60 mil column, white-only footnote; guarantee and roll-size tables
Approximate white-membrane values. Separate minimum-60 variant is also offered.
GAF system guarantee. Additional requirements apply. Fungi and other biological growth are excluded. Confirm the applicable guarantee and its coverage.
COMEG876-PDF-0726 · pp. 1–2, Features, footnotes and Available Guarantees
System eligibility determines the term and coverage.
ASTM D751. Factory seam; membrane failure. GAF also prints 645 N. Field-weld acceptance requires separate evidence.
COMEG876-PDF-0726 · p. 2, Physical Properties, nominal 60-mil column
Approximate test values for white membrane; manufacturing variation applies.
ASTM D471. Water absorption; exposure duration and temperature are unstated.
COMEG876-PDF-0726 · p. 2, Physical Properties, nominal 60-mil column
Approximate test values for white membrane; manufacturing variation applies.
Physical Properties. The data sheet reports thickness over scrim. Fiber composition is unstated.
COMEG876-PDF-0726 · p. 2, Physical Properties, nominal 60-mil column
Approximate test values for white membrane; manufacturing variation applies.
Installation and Features. For adhered systems select one of the listed GAF adhesives and follow the applicable system instructions.
COMEG876-PDF-0726 · p. 1, Installation and Features
Standard smooth membrane; separately specified options and assembly details require confirmation.
TPO roofing membrane. Smooth reinforced sheet, nominal 60 mil; reference color white where applicable.
Johns Manville Corporation · Official product page
ASTM D751. Published nominal designation. Assessed only as a dimensional designation.
RS-8633 8-21, replaces 4-21 · pp. 1–2, Packaging and Dimensions; Tested Physical Properties; Supplemental Testing
Current product page, older posted sheet. PDS row labels include ‘min’ while the footer calls results typical averages. Retain as reported, not guaranteed.
ASTM D7635. PDS row says min; footer qualifies data as typical/variable.
RS-8633 8-21, replaces 4-21 · pp. 1–2, Packaging and Dimensions; Tested Physical Properties; Supplemental Testing
Current product page, older posted sheet. PDS row labels include ‘min’ while the footer calls results typical averages. Retain as reported, not guaranteed.
ASTM D751. MD × XMD; PDS row says min, footer qualifies values.
RS-8633 8-21, replaces 4-21 · pp. 1–2, Packaging and Dimensions; Tested Physical Properties; Supplemental Testing
Current product page, older posted sheet. PDS row labels include ‘min’ while the footer calls results typical averages. Retain as reported, not guaranteed.
ASTM D751. MD × XMD.
RS-8633 8-21, replaces 4-21 · pp. 1–2, Packaging and Dimensions; Tested Physical Properties; Supplemental Testing
Current product page, older posted sheet. PDS row labels include ‘min’ while the footer calls results typical averages. Retain as reported, not guaranteed.
ASTM D751. MD × XMD; specimen geometry unspecified.
RS-8633 8-21, replaces 4-21 · pp. 1–2, Packaging and Dimensions; Tested Physical Properties; Supplemental Testing
Current product page, older posted sheet. PDS row labels include ‘min’ while the footer calls results typical averages. Retain as reported, not guaranteed.
ASTM D1204. 6 h at 158°F.
RS-8633 8-21, replaces 4-21 · pp. 1–2, Packaging and Dimensions; Tested Physical Properties; Supplemental Testing
Current product page, older posted sheet. PDS row labels include ‘min’ while the footer calls results typical averages. Retain as reported, not guaranteed.
ASTM D5602. Test load, not failure load.
RS-8633 8-21, replaces 4-21 · pp. 1–2, Packaging and Dimensions; Tested Physical Properties; Supplemental Testing
Current product page, older posted sheet. PDS row labels include ‘min’ while the footer calls results typical averages. Retain as reported, not guaranteed.
ASTM D5635. Test energy; direction not identified.
RS-8633 8-21, replaces 4-21 · pp. 1–2, Packaging and Dimensions; Tested Physical Properties; Supplemental Testing
Current product page, older posted sheet. PDS row labels include ‘min’ while the footer calls results typical averages. Retain as reported, not guaranteed.
ASTM D2137. RS-8633 p. 2, brittleness point threshold. Distinct from the ASTM D2136 bend test.
RS-8633 8-21, replaces 4-21 · pp. 1–2, Packaging and Dimensions; Tested Physical Properties; Supplemental Testing
Current product page, older posted sheet. PDS row labels include ‘min’ while the footer calls results typical averages. Retain as reported, not guaranteed.
ASTM D573. 240°F; PDS row omits aging duration.
RS-8633 8-21, replaces 4-21 · pp. 1–2, Packaging and Dimensions; Tested Physical Properties; Supplemental Testing
Current product page, older posted sheet. PDS row labels include ‘min’ while the footer calls results typical averages. Retain as reported, not guaranteed.
ASTM G151 / G155. PDS result drops spectral-bandwidth units used in its threshold. Kept verbatim pending clarification.
RS-8633 8-21, replaces 4-21 · pp. 1–2, Packaging and Dimensions; Tested Physical Properties; Supplemental Testing
Current product page, older posted sheet. PDS row labels include ‘min’ while the footer calls results typical averages. Retain as reported, not guaranteed.
Product documentation. Exact 60-mil product variant. Confirm current project submittal.
RS-8633 8-21, replaces 4-21 · pp. 1–2, Packaging and Dimensions; Tested Physical Properties; Supplemental Testing
Current product page, older posted sheet. PDS row labels include ‘min’ while the footer calls results typical averages. Retain as reported, not guaranteed.
Installation/Application and System Compatibility. Follow JM TPO application guides and detail drawings. Excluded from multi-ply systems.
RS-8633 8-21, replaces 4-21 · p. 1, Installation/Application and System Compatibility
Current application guides govern the project configuration.
ASTM D751. Factory seam result; JM also prints 498 N. The row is labeled minimum; the document qualifies the result as a typical average.
RS-8633 8-21, replaces 4-21 · p. 2, Tested Physical Properties, JM TPO 60-mil result
Row labels use minimum or maximum; the PDS describes its results as typical averages subject to variation.
ASTM D471. Water absorption result under a maximum-labeled row; JM qualifies its results as typical averages. Exposure duration and temperature are unstated.
RS-8633 8-21, replaces 4-21 · p. 2, Tested Physical Properties, JM TPO 60-mil result
Row labels use minimum or maximum; the PDS describes its results as typical averages subject to variation.
Product Details. Johns Manville describes polyester fabric. The 60-mil data sheet identifies a fabric scrim.
Official product page; revision unstated · Product Details; standard JM TPO Roofing Membrane
Family-level fiber description; the 60-mil PDS identifies the scrim layer.
Peak Advantage Guarantee Information. The term table gives no no-dollar-limit designation. Standard sale terms include a limited warranty and limitation of remedy. Confirm the issued system guarantee and coverage.
RS-8633 8-21, replaces 4-21 · p. 1, Peak Advantage Guarantee Information; p. 2, standard Terms and Conditions
Term options for JM TPO 60 mil; issued guarantee determines coverage.
TPO roofing membrane. Smooth reinforced sheet, nominal 60 mil; reference color white where applicable.
Amrize Building Envelope LLC · Official product page
ASTM D751. Published nominal designation. Assessed only as a dimensional designation.
TIS 201 · 2026-10-14 · pp. 1–4, description, environmental metrics, Typical Properties 60-mil column and product sizes
Standard UltraPly only. Separate 60-mil minimum-thickness sheet is outside cohort.
ASTM D7635. Edition and full laboratory protocol not stated.
TIS 201 · 2026-10-14 · pp. 1–4, description, environmental metrics, Typical Properties 60-mil column and product sizes
Standard UltraPly only. Separate 60-mil minimum-thickness sheet is outside cohort.
Product documentation. Exact 60-mil product variant. Confirm current project submittal.
TIS 201 · 2026-10-14 · pp. 1–4, description, environmental metrics, Typical Properties 60-mil column and product sizes
Standard UltraPly only. Separate 60-mil minimum-thickness sheet is outside cohort.
ASTM D751 Grab Method. Direction unspecified.
TIS 201 · 2026-10-14 · pp. 1–4, description, environmental metrics, Typical Properties 60-mil column and product sizes
Standard UltraPly only. Separate 60-mil minimum-thickness sheet is outside cohort.
ASTM D751 Grab Method. Reinforcement break; direction unspecified.
TIS 201 · 2026-10-14 · pp. 1–4, description, environmental metrics, Typical Properties 60-mil column and product sizes
Standard UltraPly only. Separate 60-mil minimum-thickness sheet is outside cohort.
ASTM D751. Specimen and direction unspecified.
TIS 201 · 2026-10-14 · pp. 1–4, description, environmental metrics, Typical Properties 60-mil column and product sizes
Standard UltraPly only. Separate 60-mil minimum-thickness sheet is outside cohort.
ASTM D1204. 6 h at 158°F.
TIS 201 · 2026-10-14 · pp. 1–4, description, environmental metrics, Typical Properties 60-mil column and product sizes
Standard UltraPly only. Separate 60-mil minimum-thickness sheet is outside cohort.
ASTM D5602. Source uses mass notation. Force conversion withheld without load definition.
TIS 201 · 2026-10-14 · pp. 1–4, description, environmental metrics, Typical Properties 60-mil column and product sizes
Standard UltraPly only. Separate 60-mil minimum-thickness sheet is outside cohort.
ASTM D5635. Direction-specific thresholds. No universal puncture rating.
TIS 201 · 2026-10-14 · pp. 1–4, description, environmental metrics, Typical Properties 60-mil column and product sizes
Standard UltraPly only. Separate 60-mil minimum-thickness sheet is outside cohort.
ASTM D573 conditioning; ASTM D751 retention checks. 5,376 h at 240 °F. Retained directions unspecified.
TIS 201 · 2026-10-14 · pp. 1–4, description, environmental metrics, Typical Properties 60-mil column and product sizes
Standard UltraPly only. Separate 60-mil minimum-thickness sheet is outside cohort.
ASTM G155. 176°F black panel; 3 in mandrel; inspected at 7×.
TIS 201 · 2026-10-14 · pp. 1–4, description, environmental metrics, Typical Properties 60-mil column and product sizes
Standard UltraPly only. Separate 60-mil minimum-thickness sheet is outside cohort.
Method of Application. Elevate calls for a smooth, dry substrate with contaminants and sharp projections removed. The cited instructions call for repairing rough areas and filling openings wider than ¼ in (6.3 mm in the source). Consult the current Elevate specifications.
TIS 201 · 2026-10-14 · p. 1, Method of Application
Product instructions do not establish approval of a complete assembly.
ASTM D2137. Brittleness point; distinct from ASTM D2136 low-temperature bend.
TIS 201 · 2026-10-14 · pp. 1–4, description, environmental metrics, Typical Properties 60-mil column and product sizes
Standard UltraPly only. Separate 60-mil minimum-thickness sheet is outside cohort.
PDS product sizes. 100-ft rolls in White, Tan and Gray; 200-ft White rolls on listed widths other than 6 ft 2 in.
TIS 201 · 2026-10-14 · pp. 1–4, description, environmental metrics, Typical Properties 60-mil column and product sizes
Standard UltraPly only. Separate 60-mil minimum-thickness sheet is outside cohort.
ASTM D471. Water absorption for the 60-mil column. The less-than figure is a reported upper bound. Exposure duration and temperature are unstated.
TIS 201 · 2026-10-14 · p. 3, Typical Properties, 60-mil Water Absorption
Standard UltraPly TPO. No individual measured value is given.
TPO roofing membrane. Smooth reinforced sheet, nominal 60 mil; reference color white where applicable.
Carlisle Construction Materials LLC · Official product page
ASTM D751. Published nominal designation. Assessed only as a dimensional designation.
01.28.26 · pp. 1 and 4, overview and Typical Properties, 60-mil column; radiative table
Standard reinforced sheet. Minimum, SAT and fleece-backed variants excluded.
ASTM D7635. Optical method, average of three areas.
01.28.26 · pp. 1 and 4, overview and Typical Properties, 60-mil column; radiative table
Standard reinforced sheet. Minimum, SAT and fleece-backed variants excluded.
ASTM D751 Grab Method. Separate source minimum is 250 lbf. Direction unstated.
01.28.26 · pp. 1 and 4, overview and Typical Properties, 60-mil column; radiative table
Standard reinforced sheet. Minimum, SAT and fleece-backed variants excluded.
ASTM D751 Grab Method. Reinforcement break, direction unstated.
01.28.26 · pp. 1 and 4, overview and Typical Properties, 60-mil column; radiative table
Standard reinforced sheet. Minimum, SAT and fleece-backed variants excluded.
ASTM D751 Procedure B. 8 × 8 in specimen; direction unstated.
01.28.26 · pp. 1 and 4, overview and Typical Properties, 60-mil column; radiative table
Standard reinforced sheet. Minimum, SAT and fleece-backed variants excluded.
PDS overview. Reinforcement encapsulated between TPO plies.
01.28.26 · pp. 1 and 4, overview and Typical Properties, 60-mil column; radiative table
Standard reinforced sheet. Minimum, SAT and fleece-backed variants excluded.
ASTM D1204. 6 h at 158 °F. Direction omitted.
01.28.26 · pp. 1 and 4, overview and Typical Properties, 60-mil column; radiative table
Standard reinforced sheet. Minimum, SAT and fleece-backed variants excluded.
ASTM D573. 32 weeks at 240 °F or 8 weeks at 275 °F; no cracking on 3-in mandrel. Protocol used for individual sample is unspecified.
01.28.26 · pp. 1 and 4, overview and Typical Properties, 60-mil column; radiative table
Standard reinforced sheet. Minimum, SAT and fleece-backed variants excluded.
ASTM G155. No cracks at 7×; reported requirement 10,080 kJ/m² (4,000 h at 0.70 W/m²). Individual dose/endpoint undisclosed.
01.28.26 · pp. 1 and 4, overview and Typical Properties, 60-mil column; radiative table
Standard reinforced sheet. Minimum, SAT and fleece-backed variants excluded.
ASTM D2137. Brittleness point; distinct from ASTM D2136 low-temperature bend.
01.28.26 · pp. 1 and 4, overview and Typical Properties, 60-mil column; radiative table
Standard reinforced sheet. Minimum, SAT and fleece-backed variants excluded.
PDS product family overview. Confirm exact 60-mil color and widths on current order schedule.
01.28.26 · pp. 1 and 4, overview and Typical Properties, 60-mil column; radiative table
Standard reinforced sheet. Minimum, SAT and fleece-backed variants excluded.
Installation. The Carlisle system details identify the adhesives, plates or fasteners for each attachment method. The sheet specifies Carlisle Weathered Membrane Cleaner for weather-exposed membrane before welding. Consult the applicable details.
01.28.26 · p. 2, Installation
Substrate, fastening and assembly details depend on system configuration.
ASTM D751 Grab Method. Factory seam minimum; Carlisle prints 290 N. A separate typical factory seam result is unstated.
01.28.26 · p. 4, Typical Properties, requirement and 60-mil columns
Reported minima and typical values retain their separate bases.
ASTM D1876. Reported typical field-seam peel strength for 60 mil (10.5 kN/m as printed). The separate listed minimum is 25 lbf/in (4.4 kN/m). Installed field-weld acceptance requires project checks.
01.28.26 · p. 4, Typical Properties, requirement and 60-mil columns
Reported minima and typical values retain their separate bases.
ASTM D471. Water absorption by mass after top-surface water exposure for 166 hours at 158 °F. The table separately lists a ±3.0% maximum.
01.28.26 · p. 4, Typical Properties, requirement and 60-mil columns
Reported minima and typical values retain their separate bases.
Precautions. The retained PDS gives no warranty duration for the standard reinforced 60-mil sheet. Confirm duration and coverage for the proposed assembly.
01.28.26 · p. 2, Precautions
Color-fading qualification only.
PVC roofing membrane. Smooth reinforced sheet, nominal 60 mil; reference color white where applicable.
GAF Materials LLC · Official product page
ASTM D2136. Low-temperature bend; not installation temperature.
COMEG992-PDF-0426 · p. 2, Physical Properties, Low-Temperature Bend, 60-mil column
Reported ASTM D2136 bend pass. Project and installation temperatures require separate assessment.
Product documentation. Exact 60-mil product variant. Confirm current project submittal.
Live catalog; revision unstated · Product details and related specifications
Application and Features. The PDS lists EverGuard #2331 Bonding Adhesive, PVC Quick Spray and PVC Quick Lay for adhered applications. Follow the specific GAF system instructions.
COMEG992-PDF-0426 · p. 1, Application and Features
System-level installation options. Confirm exact assembly with GAF.
ASTM D751. Reported factory seam percentage; table lists a 75% requirement and does not name the denominator. Field-weld acceptance requires separate evidence.
COMEG992-PDF-0426 · p. 2, Physical Properties, 60-mil column
Approximate manufacturer results subject to variation. Original figure bases retained.
ASTM D570. Weight change after water immersion; exposure duration and temperature are unstated.
COMEG992-PDF-0426 · p. 2, Physical Properties, 60-mil column
Approximate manufacturer results subject to variation. Original figure bases retained.
Physical Properties. The data sheet reports thickness over scrim. Fiber composition is unstated.
COMEG992-PDF-0426 · p. 2, Physical Properties, 60-mil column
Approximate manufacturer results subject to variation. Original figure bases retained.
GAF system guarantee. System-family maximum; the sheet gives no 60-mil-specific term. Conditions apply. Chemical exposure, grease, animal fats and jet fuel are excluded.
COMEG992-PDF-0426 · p. 1, Features and guarantee footnotes
Qualified systems only; verify eligibility and coverage for the exact configuration.
ASTM D751. Overall thickness, 60-mil column. GAF reports approximate guide values subject to manufacturing variation.
COMEG992-PDF-0426 · p. 2, Physical Properties, Overall Thickness, 60-mil column
GAF reports 1.52 mm as the metric equivalent. This table does not establish a guaranteed minimum or satisfy an assembly minimum.
PVC roofing membrane. Smooth reinforced sheet, nominal 60 mil; reference color white where applicable.
Johns Manville Corporation · Official product page
ASTM D751. Published nominal designation. Assessed only as a dimensional designation.
RS-8018 10-25, replaces 5-24 · pp. 1–2, Manufactured Physical Properties; Guarantee and Packaging tables
Separate from PVC with Elvaloy KEE, SD Plus MIN and SD Plus FB.
ASTM D7635. PDS row labels min; product result is not encoded as a contractual guarantee.
RS-8018 10-25, replaces 5-24 · pp. 1–2, Manufactured Physical Properties; Guarantee and Packaging tables
Separate from PVC with Elvaloy KEE, SD Plus MIN and SD Plus FB.
Product documentation. Exact 60-mil product variant. Confirm current project submittal.
RS-8018 10-25, replaces 5-24 · pp. 1–2, Manufactured Physical Properties; Guarantee and Packaging tables
Separate from PVC with Elvaloy KEE, SD Plus MIN and SD Plus FB.
ASTM D751. Procedure and direction unspecified.
RS-8018 10-25, replaces 5-24 · pp. 1–2, Manufactured Physical Properties; Guarantee and Packaging tables
Separate from PVC with Elvaloy KEE, SD Plus MIN and SD Plus FB.
ASTM D751. Direction unspecified.
RS-8018 10-25, replaces 5-24 · pp. 1–2, Manufactured Physical Properties; Guarantee and Packaging tables
Separate from PVC with Elvaloy KEE, SD Plus MIN and SD Plus FB.
ASTM D751. Specimen unspecified.
RS-8018 10-25, replaces 5-24 · pp. 1–2, Manufactured Physical Properties; Guarantee and Packaging tables
Separate from PVC with Elvaloy KEE, SD Plus MIN and SD Plus FB.
ASTM D1204. 6 h at 176°F.
RS-8018 10-25, replaces 5-24 · pp. 1–2, Manufactured Physical Properties; Guarantee and Packaging tables
Separate from PVC with Elvaloy KEE, SD Plus MIN and SD Plus FB.
ASTM D5602. Test threshold, not failure force.
RS-8018 10-25, replaces 5-24 · pp. 1–2, Manufactured Physical Properties; Guarantee and Packaging tables
Separate from PVC with Elvaloy KEE, SD Plus MIN and SD Plus FB.
ASTM D5635. Test threshold, not failure energy.
RS-8018 10-25, replaces 5-24 · pp. 1–2, Manufactured Physical Properties; Guarantee and Packaging tables
Separate from PVC with Elvaloy KEE, SD Plus MIN and SD Plus FB.
ASTM D2136. Low-temperature bend; not installation temperature.
RS-8018 10-25, replaces 5-24 · pp. 1–2, Manufactured Physical Properties; Guarantee and Packaging tables
Separate from PVC with Elvaloy KEE, SD Plus MIN and SD Plus FB.
ASTM D3045 / D751. 56 days at 176°F; post-aging results.
RS-8018 10-25, replaces 5-24 · pp. 1–2, Manufactured Physical Properties; Guarantee and Packaging tables
Separate from PVC with Elvaloy KEE, SD Plus MIN and SD Plus FB.
ASTM G154. Fluorescent weathering. PDS lists 5,000 h in requirement column only.
RS-8018 10-25, replaces 5-24 · pp. 1–2, Manufactured Physical Properties; Guarantee and Packaging tables
Separate from PVC with Elvaloy KEE, SD Plus MIN and SD Plus FB.
Product documentation. Exact 60-mil product variant. Confirm current project submittal.
RS-8018 10-25, replaces 5-24 · pp. 1–2, Manufactured Physical Properties; Guarantee and Packaging tables
Separate from PVC with Elvaloy KEE, SD Plus MIN and SD Plus FB.
Installation/Application and Codes and Approvals. Install cap side up using the lap line and production code to identify it. Follow JM's application guides and details. Excluded from multi-ply systems.
RS-8018 10-25, replaces 5-24 · p. 1, Installation/Application, Codes and Approvals and System Compatibility
Current application guides govern the project configuration.
Product documentation. Exact 60-mil product variant. Confirm current project submittal.
RS-8018 10-25, replaces 5-24 · pp. 1–2, Manufactured Physical Properties; Guarantee and Packaging tables
Separate from PVC with Elvaloy KEE, SD Plus MIN and SD Plus FB.
Product documentation. Confirm eligibility for the submitted configuration and obtain the actual guarantee. Standard sale terms include a limited warranty and limitation of remedy.
RS-8018 10-25, replaces 5-24 · p. 1, Peak Advantage Guarantee Information; p. 2, standard Terms and Conditions
The table labels terms NDL for the eligible systems listed. Standard sale terms also include a limited warranty and limitation of remedy.
ASTM D751. Manufacturer's seam result; 75% is the requirement shown. Factory versus field is unstated. Row labeled minimum; source qualifies its results as typical averages.
RS-8018 10-25, replaces 5-24 · p. 2, Manufactured Physical Properties, 60-mil result
PDS identifies maximum and minimum rows; it qualifies product properties as typical averages.
ASTM D570 modified. Reported weight change after immersion equals the stated 3.0% maximum. The modified procedure, duration and temperature are unstated.
RS-8018 10-25, replaces 5-24 · p. 2, Manufactured Physical Properties, 60-mil result
PDS identifies maximum and minimum rows; it qualifies product properties as typical averages.